Bleeding Platform Lift Circuit
This procedure is necessary when left-hand cylinder is setting down on cylinder lock and right-hand cylinder is fully extended. If left-hand side of machine does not raise up, bleed oil from right-hand cylinder according to following instructions.
1.
Engage right-hand cylinder lock (A).
2.
Wrap a rag around right-hand cylinder fitting.
3.
Loosen fitting (B) and release oil until right-hand cylinder rests on cylinder lock.
4.
Tighten fitting.
5.
Raise platform and disengage cylinder locks.
6.
Lower platform.
|