Every 100 Hours: Cutterbar Input Drive Gear Case-Checking Oil Level

1. Raise left-hand side front door to access gear case. (See Raising and Lowering Front Doors and Curtains in Operating the Mower-Conditioner section.)

2. Remove shield (A).

3. Remove plug (B) to check oil level. Oil should be level with bottom of port. Fill as necessary, with specified oil. (See Gear Case Oil in this section.)

4. Apply pipe sealant with TEFLON ® , or equivalent, on threads of plug. Install plug.

IMPORTANT: When installing left-hand converging drum shield (A), adjust clearance between shield and converging drum according to specifications.

5. Install shield (A). Make sure clearance between shield and top of converging drum is according to specifications.

Specification

Shield-to-Converging Drum -Distance 5 mm (3/16 in.)

6. Lower front door.

NOTE: Specific oil contained in cutterbar input drive gear case (See Gear Case Oil in this section.) lasts the machine life and never needs to be changed.

E41436
E41494


A-Shield
B-Plug

TEFLON is a registered trademark of DuPont Company.

OUCC006,00002A4 -19-10NOV00-1/1