Adjusting Lower Crop Shields
NOTE:
Lower crop shields are located at left and right-hand ends. Right-hand end shown, left-hand end similar.
1.
Raise front platform doors.
2.
Loosen mounting hardware on lower crop shield (A).
3.
Position crop shield to obtain clearances, within specifications, at the following locations:
Specification
Bottom of shield-to-Accelerator (B)
-Clearance
|
5-8 mm (3/16-5/16 in.)
|
End of Shield-to-Converging Drum (C)
-Clearance
|
2-4 mm (3/32-5/32 in.)
|
4.
Tighten mounting hardware.
5.
Lower front platform doors.
|