Each Season: Phasing Cylinders

NOTE: Set tractor SCV to maximum flow.

1. Lower machine to the ground.

2. Raise machine and continue to hold SCV lever at least 5 seconds until slave cylinder is completely extended. Cylinder should be extended according to specifications.

Specification

946 -Distance 203 ± 3 mm (8 ± 1/8 in.)
956 -Distance 254 ± 3 mm (10 ± 1/8 in.)

3. Lower machine and continue to hold SCV lever until slave cylinder is completely retracted.

4. If slave cylinder does not retract, check for binding or obstruction of linkage at both the master and the slave cylinder.

5. If master cylinder is retracted, a rephasing groove may be plugged. (See your John Deere dealer.)

OUCC006,00002AF -19-17NOV00-1/1