BaleTrak Control Monitor

Symptom Problem Solution

Twine or net tying settings not constant with different sized bales.

Lower belt drive roll sensor not connected, defective or not correctly adjusted.

Reconnect or readjust sensor. Replace if necessary. See sections "BaleTrak Monitor Service" and "Service".

Bale size potentiometer not connected or defective.

Reconnect or replace potentiometer. See sections "BaleTrak Monitor Service" and "Service".

No pictogram displayed at LCD screen when switching ON.

Monitor not connected.

Connect monitor.

Battery wiring harness not correctly connected.

Reconnect properly. See section "Preparing the Tractor".

Top bar(s) on the LCD screen never come on.

Bale shape potentiometer adjustment not fine enough.

Adjust potentiometer finely. See section "Setting Up the Baler".

Erratic monitor functions.

Battery charge level too low.

Battery should deliver at least 20 A.

Battery voltage level below 7 V.

Monitor requires at least 12 V to function properly. Check or replace tractor battery.

Battery wiring harness not correctly connected.

Reconnect properly. See section "Preparing the Tractor".

Desired bale diameter can not be achieved.

Bale size potentiometer not correctly adjusted

Adjust bale size potentiometer. See section "Operating BaleTrak Monitor".

Bale size fine tuned.

Reset to zero value. See section "Operating BaleTrak Monitor".

Monitor not set for baler model.

See your John Deere dealer.

Oversize alarm sounds at smaller bale size than the maximum.

Oversize switch not correctly adjusted.

Adjust oversize switch. See section "Service".

Monitor not set for baler model.

See your John Deere dealer.

OUCC007,0000EAE -19-15OCT04-1/1