Twine or net tying settings not constant with different sized bales.
|
Lower belt drive roll sensor not connected, defective or not correctly adjusted.
|
Reconnect or readjust sensor. Replace if necessary. See sections "BaleTrak Monitor Service" and "Service".
|
|
|
Bale size potentiometer not connected or defective.
|
Reconnect or replace potentiometer. See sections "BaleTrak Monitor Service" and "Service".
|
|
No pictogram displayed at LCD screen when switching ON.
|
Monitor not connected.
|
Connect monitor.
|
|
|
Battery wiring harness not correctly connected.
|
Reconnect properly. See section "Preparing the Tractor".
|
|
Top bar(s) on the LCD screen never come on.
|
Bale shape potentiometer adjustment not fine enough.
|
Adjust potentiometer finely. See section "Setting Up the Baler".
|
|
Erratic monitor functions.
|
Battery charge level too low.
|
Battery should deliver at least 20 A.
|
|
|
Battery voltage level below 7 V.
|
Monitor requires at least 12 V to function properly. Check or replace tractor battery.
|
|
|
Battery wiring harness not correctly connected.
|
Reconnect properly. See section "Preparing the Tractor".
|
|
Desired bale diameter can not be achieved.
|
Bale size potentiometer not correctly adjusted
|
Adjust bale size potentiometer. See section "Operating BaleTrak Monitor".
|
|
|
Bale size fine tuned.
|
Reset to zero value. See section "Operating BaleTrak Monitor".
|
|
|
Monitor not set for baler model.
|
See your John Deere dealer.
|
|
Oversize alarm sounds at smaller bale size than the maximum.
|
Oversize switch not correctly adjusted.
|
Adjust oversize switch. See section "Service".
|
|
|
Monitor not set for baler model.
|
See your John Deere dealer.
|