Description of ELC Plus Monitor with Net/Twine Tying Switch on Monitor
ELC Plus monitor allows to control twine or net tying.
Switch (I) allows to select the tying device.
NOTE:
The middle position of the switch (I) is used to switch off the monitor.
A-Monitor
B-End bale distribution potentiometer; Net tie density potentiometer
C-Middle twine distribution potentiometer
D-Re-extension time potentiometer; Actuator positioning potentiometer
E-Manual control switch
F-"START" button
G-Adjusting screw
H-"IN CYCLE" light
I-Net/Twine tying switch
|