Diagnostic Trouble Code List

The diagnostic trouble codes are given in the following table:

Battery
Diagnostic trouble code Description Solution How to clear the code displayed
E001 Voltage drop while actuator is on Check wires and connectors.
Check battery.
Check alternator.
See "Channel 019" in this section.
Press "Minus" key when actuator is off
E002 Battery voltage below 11.2 V Check wires and connectors.
Check battery.
Check alternator.
See "Channel 019" in this section.
Disappears when fault is removed
E003 Battery voltage above 16 V Check alternator.
See "Channel 019" in this section.
Disappears when fault is removed
Right bale shape potentiometer
Diagnostic trouble code Description Solution How to clear the code displayed
E112 Open circuit or grounded circuit Check wires and connectors.
Check potentiometer.
Disappears after 5 seconds
E113 Shorted circuit Check wires and connectors.
Check potentiometer.
Disappears after 5 seconds
E114 Right bale shape below minimum value Check potentiometer adjustment. See "Channel 006" in this section. Disappears after 5 seconds
E115 Right bale shape above maximum value Check potentiometer adjustment. See "Channel 006" in this section. Disappears after 5 seconds
Left bale shape potentiometer
Diagnostic trouble code Description Solution How to clear the code displayed
E122 Open circuit or grounded circuit Check wires and connectors.
Check potentiometer.
Disappears after 5 seconds
E123 Shorted circuit Check wires and connectors.
Check potentiometer.
Disappears after 5 seconds
E124 Left bale shape below minimum value Check potentiometer adjustment. See "Channel 007" in this section. Disappears after 5 seconds
E125 Left bale shape above maximum value Check potentiometer adjustment. See "Channel 007" in this section. Disappears after 5 seconds

 

OUCC006,00012FE -19-26SEP07-1/5


Twine actuator
Diagnostic trouble code Description Solution How to clear the code displayed
E201 Twine actuator disconnected Check wires and connectors. Press "Minus" key when actuator is off
E202 Twine actuator faulty or jammed Check twine actuator. Press "Minus" key when actuator is off
E203 Twine actuator wiring harness resistance too high Check wires and connectors.
Check twine actuator.
Press "Minus" key when actuator is off
E204 Shorted circuit Check wires and connectors. Press "Minus" key when fault is removed
E205 Actuator wire shorted to ground Check wires and connectors. Press "Minus" key when fault is removed
Net actuator
Diagnostic trouble code Description Solution How to clear the code displayed
E211 Net actuator disconnected Check wires and connectors. Press "Minus" key when actuator is off
E212 Net actuator faulty Check net actuator. Press "Minus" key when actuator is off
E213 Net actuator wiring harness resistance too high Check wires and connectors.
Check net actuator.
Press "Minus" key when actuator is off
E214 Shorted circuit Check wires and connectors. Press "Minus" key when fault is removed
E215 Actuator wire shorted to ground Check wires and connectors. Press "Minus" key when fault is removed
Pickup valve
Diagnostic trouble code Description Solution How to clear the code displayed
E231 Pickup valve disconnected Check wires and connectors. Press "Minus" key when fault is removed
E232 Pickup valve shorted to ground Check wires and connectors.
Check pickup valve.
Press "Minus" key when fault is removed
E233 Shorted circuit Check wires and connectors.
Check pickup valve.
Press "Minus" key when fault is removed
Knife valve
Diagnostic trouble code Description Solution How to clear the code displayed
E241 Knife valve disconnected Check wires and connectors. Press "Minus" key when fault is removed
E242 Knife valve shorted to ground Check wires and connectors.
Check knife valve.
Press "Minus" key when fault is removed
E243 Shorted circuit Check wires and connectors.
Check knife valve.
Press "Minus" key when fault is removed

 

OUCC006,00012FE -19-26SEP07-2/5


Reverser valve
Diagnostic trouble code Description Solution How to clear the code displayed
E251 Reverser valve disconnected Check wires and connectors. Press "Minus" key when fault is removed
E252 Reverser valve shorted to ground Check wires and connectors.
Check reverser valve.
Press "Minus" key when fault is removed
E253 Shorted circuit Check wires and connectors.
Check reverser valve.
Press "Minus" key when fault is removed
Baler rotation speed sensor
Diagnostic trouble code Description Solution How to clear the code displayed
E311 Baler rotation speed sensor disconnected Check wires and connectors. Disappears after 5 seconds
E312 Baler rotation speed below minimum Check sensor adjustment. See "Adjusting Baler Rotation Speed Sensor" in "Service" section.
Check sensor. See "Channel 017" in this section.
Disappears after 5 seconds
E313 Baler rotation speed above maximum Check sensor adjustment. See "Adjusting Baler Rotation Speed Sensor" in "Service" section.
Check sensor. See "Channel 017" in this section.
Disappears after 5 seconds
Twine pulley sensor
Diagnostic trouble code Description Solution How to clear the code displayed
E321 Twine ball is empty or twine is not tied around the bale Replace twine ball.
Check twine routing. See "Routing Twine Through Guides" in "Preparing the Baler" section.
Check twine pulley sensor adjustment. See "Adjusting Twine Pulley Sensor" in "Service" section.
Press "Minus" key when fault is removed
E322 Twine not cut Check cutter anvil adjustment. See "Adjusting Single Arm Twine Cutter Anvil" in "Service" section. Press "Minus" key when fault is removed

 

OUCC006,00012FE -19-26SEP07-3/5


Net cut switch (baler with standard net tying device)
Diagnostic trouble code Description Solution How to clear the code displayed
E401 Net cut switch always open Check wires and connectors.
Check net cut switch adjustment. See "Adjusting Net Cut Switch" in "Service" section.
Check net cut switch. See "Channel 012" in this section.
Disappears when fault is removed
E402 Net cut switch always closed Check wires and connectors.
Check net cut switch adjustment. See "Adjusting Net Cut Switch" in "Service" section.
Check net cut switch. See "Channel 012" in this section.
Disappears when fault is removed
Net cut sensor (baler with CoverEdge™ net tying device)
Diagnostic trouble code Description Solution How to clear the code displayed
E401 No net on bale Check wires and connectors.
Check net cut sensor adjustment. See "Adjusting Net Cut Sensor" in "Service" section.
Check net cut sensor. See "Channel 012" in this section.
Disappears when fault is removed
E402 Net not cut Check wires and connectors.
Check net cut sensor adjustment. See "Adjusting Net Cut Sensor" in "Service" section.
Check net cut sensor. See "Channel 012" in this section.
Disappears when fault is removed
Oversize/gate switch
Diagnostic trouble code Description Solution How to clear the code displayed
E411 Oversize/gate switch always open Check wires and connectors.
Check oversize/gate switch adjustment. See "Adjusting Oversize/Gate Switch and Full-Size Bale Switch" in "Service" section.
Check oversize/gate switch. See "Channel 014" in this section.
Disappears after 5 seconds
E412 Oversize/gate switch always closed Check wires and connectors.
Check oversize/gate switch adjustment. See "Adjusting Oversize/Gate Switch and Full-Size Bale Switch" in "Service" section.
Check oversize/gate switch. See "Channel 014" in this section.
Disappears after 5 seconds

 

CoverEdge is a trademark of Deere & Company

OUCC006,00012FE -19-26SEP07-4/5


Full-size bale switch
Diagnostic trouble code Description Solution How to clear the code displayed
E431 Full-size bale switch always open Check wires and connectors.
Check full-size bale switch adjustment. See "Adjusting Oversize/Gate Switch and Full-Size Bale Switch" in "Service" section.
Check full-size bale switch. See "Channel 013" in this section.
Press "Minus" key when fault is removed
E432 Full-size bale switch always closed Check wires and connectors.
Check full-size bale switch adjustment. See "Adjusting Oversize/Gate Switch and Full-Size Bale Switch" in "Service" section.
Check full-size bale switch. See "Channel 013" in this section.
Press "Minus" key when fault is removed
EPROM
Diagnostic trouble code Description Solution How to clear the code displayed
E601 Memory corrupt Do your personal settings again. Disappears after 5 seconds
E602 Memory corrupt Check your personal settings. Disappears after 5 seconds
E603 Memory corrupt See your John Deere dealer. Disappears when fault is removed
E604 Memory corrupt Check your personal settings. Disappears after 5 seconds
E605 Memory corrupt See your John Deere dealer. Disappears when fault is removed

 

OUCC006,00012FE -19-26SEP07-5/5