4.
Check that counterknife (A) is against net knife (D) all across its width.
IMPORTANT:
Contact should occur on the medium area of the sharp side of the knife as shown.
The gap (E) in not touching area should not exceed the following specifications:
Specification
Counterknife to Knife
-Gap
|
0.5 mm maximum
|
0.02 in. maximum
|
If necessary, adjust the gap (E) as follows:
a.
Loosen nuts (B) and (F).
b.
Move counterknife (A) and counterknife support (C) to obtain specified gap (E).
c.
Tighten nuts (B) and (F).
A-Counterknife
B-Nuts
C-Counterknife support
D-Knife
E-0.5 mm (0.02 in.) maximum
F-Nuts
|