Diagnostic Mode: User Parameters

The user parameters allow the operator to reset all settings to factory default settings, to select special twine tying programs, to set user parameters and to check and adjust electrical components which are connected to the monitor.

The user parameters are stored in several "Channels" from "CH001" to "CH032".

Switching On the Monitor in Diagnostic Mode

Monitor off, press and hold the COUNTER key (A), then switch ON the monitor by pressing the ON/OFF key (B).

During the power-up, all the LCD screen pictograms are displayed and the buzzer beeps for one second.

Then, "CH001" is displayed on the LCD screen, the monitor is switched in diagnostic mode and the setting of channel 1 is displayed if the counter key is released.

NOTE: To switch ON the monitor in diagnostic mode, do not release the COUNTER key (A) before the LCD screen displays "CH001".

Selecting User Channel

When the monitor is switched in diagnostic mode, press and hold "COUNTER" key (A) and press "PLUS" or "MINUS" key to change the channel.

To return in normal mode and save the user parameters settings, switch OFF the monitor by pressing the ON/OFF key.


A-Counter key
B-ON/OFF key

CC1018859

CC03745,0000C3F -19-19JAN07-1/1