Replacing Precutter Knives
CAUTION:
DO NOT TAKE CHANCES. To avoid injury or death by being cut by a knife, always close shut-off valve (A) before removing or replacing knives.
Always wear gloves to handle knives.
Each knife (C) can be separately removed and replaced.
To remove and replace a knife proceed as follows:
Retract knives. (See Retracting/Engaging Precutter Knives in Operating BaleTrak Monitor Section)
Fully open the gate and secure it.
Pull the lever (B) out of its locking pin and lower it.
Knives can now easily be removed from the inside of the baler. Pull on knife (C) to remove it from bar (D) and nylon guide (E).
To install a knife, simply insert knife (C) first in nylon guide (E), then place it on the bar (D).
IMPORTANT:
When a knife is no longer required, it is recommended to install the knife slot filler (F) instead. This will avoid crop accumulation at the hole provided by the missing knife.
Raise and secure lever (B) in its locking pin.
Lower the gate.
Open shut-off valve (A).
|