Channel 018: Test of Actuator Current Consumption

"CH018" allows to display the current consumption of either the twine or net actuator.

Press "EXTEND" (A) or "RETRACT" (B) key to move the actuator of the selected tying system. While the actuator moves, the current consumption in ampere is displayed on the LCD screen.

Display should show a current flow reading between 2 and 8 amperes while actuator motor is operating during mid stroke (no load).

Continue to activate the actuator to full stroke position. When twine actuator is fully extended or retracted, display should show stall current between 18 and 27 amperes. When net actuator is fully extended or retracted, display should show stall current between 12 and 20 amperes.

  • Readings below normal indicate low tractor voltage, or poor or corroded harness connections.
  • Readings above normal indicate tying mechanical problem, faulty harness or faulty actuator.
  • Current spike reading indicates tying mechanical obstruction.