Warning Pictograms

Stop Indicator

The Stop indicator (A) is displayed when:

  • The bale reaches the preset diameter.
  • The Open Gate pictogram is displayed.
  • The Oversize Bale pictogram is displayed.
  • The Net Tying warning pictogram is displayed.
  • A diagnostic trouble code is displayed.
  • The monitor is switched on with a bale inside the baler.

Stop the tractor when the stop indicator (A) is displayed.

NOTE: The Stop indicator is displayed at start up if the net or twine actuator is disconnected or does not work.

Open Gate Pictogram

The Open Gate Pictogram (B) is displayed when the gate of the baler is opened while ejecting the bale.

Activate the tractor selective control valve lever to close the gate of the baler and switch off this pictogram.

NOTE: If the Open Gate Pictogram is displayed when the gate is correctly closed, adjust the gate switch. (See "Adjusting Gate Switch" in "Service" section).

Oversize Bale Pictogram

The Oversize Bale pictogram (C) is displayed when the bale exceeds the maximum bale diameter of the baler model. Continuing to operate with oversized bale in chamber can cause severe gate damage, bearing breakage and roll damage.

When the Oversize Bale pictogram is displayed, immediately stop the tractor. Start the tying cycle with Manual Tying Start key (see "Starting Manually an Automatic Tying Cycle" in this section), and eject the bale.

CC1018857


A-Stop indicator
B-Open gate warning
C-Oversized Bale warning
D-Net tying warning
E-Battery warning

OUCC006,0000C2A -19-20AUG04-1/2


Net Pictogram

The Net pictogram (D) is displayed when the net is not cut or when the net roll is empty. Correct the net cut problem or replace the net roll to switch off this pictogram.

Battery Pictogram

The Battery pictogram (E) and the voltage are displayed when the battery voltage is below 11.2 V or over 16 V.

CC1018857


A-Stop indicator
B-Open gate warning
C-Oversized Bale warning
D-Net tying warning
E-Battery warning