Adjusting Rotary Feeder Reverse Sensor
To adjust sensor (A), proceed as follows:
1.
Check that rotary feeder is not in reverse operating mode. See "Reversing Rotary Feeder" in "Operating BaleTrak Monitor" section.
2.
With hydraulic cylinder fully retracted, check that magnet (B) is aligned with sensor (A).
3.
Check that distance (C) between sensor (A) and magnet (B) is within specification:
Specification
Sensor to Magnet
-Distance
|
10 ± 1 mm
|
(0.4 ± 0.04 in.)
|
If necessary, adjust sensor (A) as follows:
a.
Loosen lock nuts (D) and slide sensor (A) until distance (C) is obtained.
b.
Tighten lock nuts (D).
4.
With BaleTrak
monitor, check sensor detection. See "Channel 024: Test of Rotary Feeder Reverse Sensor" in "BaleTrak Monitor Service" section.
|