Adjusting Cleaning Auger Sensor

causym CAUTION: DO NOT TAKE CHANCES! Never use any type of tool or spanner on shaft while tractor engine is running. Shut off tractor engine, remove key and wait for moving parts to come to a standstill. Always remove tool from shaft as soon as you have finished using it.

NOTE: The diagnostic trouble code E304 can appear if the cleaning auger sensor is not correctly adjusted.

1. Position a spanner on gear case output shaft and rotate baler by hand so that the gear (A) is in position shown.

2. Check that distance (D) between sensor (C) and gear (A) is within specification:

Specification

Sensor to Gear -Distance 3 ± 1 mm (0.12 ± 0.04 in.)

3. If not, loosen lock nuts (B) then slide sensor (C) until specified distance (D) is achieved.

4. Slightly tighten lock nuts (B) and rotate the baler several times to check that there is no interference between sensor and gear.

5. Check that center line of sensor (C) is aligned with center line of gear (A).

CC1028771


A-Gear
B-Lock nuts
C-Sensor
D-3 ± 1 mm (0.12 ± 0.04 in.)

OUCC006,0001294 -19-01OCT07-1/1