| Battery |
| Diagnostic trouble code |
Description |
Solution |
How to clear the code displayed |
| E001 |
Voltage drop while actuator is on |
Check wire and connectors. Check battery. Check alternator. See "Channel 019" in this section. |
Press "Minus" key when actuator is off |
| E002 |
Battery voltage below 11.2 V |
Check wire and connectors. Check battery. Check alternator. See "Channel 019" in this section. |
Disappears when fault is removed |
| E003 |
Battery voltage above 16 V |
Check alternator. See "Channel 019" in this section. |
Disappears when fault is removed |
| E102 |
Open circuit or grounded circuit |
Check wire and connectors. Check potentiometer. |
Press "Minus" key when fault is removed |
| E103 |
Shorted circuit |
Check wire and connectors. Check potentiometer. |
Press "Minus" key when fault is removed |
| E104 |
Bale size below minimum |
Check potentiometer adjustment. See "Channel 005" in this section. |
Press "Minus" key when fault is removed |
| E105 |
Bale size above maximum |
Check potentiometer adjustment. See "Channel 005" in this section. |
Press "Minus" key when fault is removed |
| E112 |
Open circuit or grounded circuit |
Check wire and connectors. Check potentiometer. |
Disappears after 5 seconds |
| E113 |
Shorted circuit |
Check wire and connectors. Check potentiometer. |
Disappears after 5 seconds |
| E114 |
Right bale shape below minimum value |
Check potentiometer adjustment. See "Channel 006" in this section. |
Disappears after 5 seconds |
| E115 |
Right bale shape above maximum value |
Check potentiometer adjustment. See "Channel 006" in this section. |
Disappears after 5 seconds |
| Left bale shape potentiometer |
| Diagnostic trouble code |
Description |
Solution |
How to clear the code displayed |
| E122 |
Open circuit or grounded circuit |
Check wire and connectors. Check potentiometer. |
Disappears after 5 seconds |
| E123 |
Shorted circuit |
Check wire and connectors. Check potentiometer. |
Disappears after 5 seconds |
| E124 |
Left bale shape below minimum value |
Check potentiometer adjustment. See "Channel 007" in this section. |
Disappears after 5 seconds |
| E125 |
Left bale shape above maximum value |
Check potentiometer adjustment. See "Channel 007" in this section. |
Disappears after 5 seconds |
| E201 |
Twine actuator disconnected |
Check wire and connectors. |
Press "Minus" key when actuator is off |
| E202 |
Twine actuator faulty or jammed |
Check twine actuator. |
Press "Minus" key when actuator is off |
| E203 |
Resistive twine actuator power line |
Check wire and connectors. Check twine actuator. |
Press "Minus" key when actuator is off |
| E204 |
Actuator wire short circuit to the battery |
Check wire and connectors. |
Press "Minus" key when fault is removed |
| E205 |
Actuator wire short circuit to the ground |
Check wire and connectors. |
Press "Minus" key when fault is removed |
| E211 |
Net actuator disconnected |
Check wire and connectors. |
Press "Minus" key when actuator is off |
| E212 |
Net actuator faulty |
Check net actuator. |
Press "Minus" key when actuator is off |
| E213 |
Resistive net actuator power line |
Check wire and connectors. Check net actuator. |
Press "Minus" key when actuator is off |
| E214 |
Actuator wire short circuit to the battery |
Check wire and connectors. |
Press "Minus" key when fault is removed |
| E215 |
Actuator wire short circuit to the ground |
Check wire and connectors. |
Press "Minus" key when fault is removed |
| Soft core valve |
| Diagnostic trouble code |
Description |
Solution |
How to clear the code displayed |
| E221 |
Soft core valve disconnected |
Check wire and connectors. |
Press "Minus" key when fault is removed |
| E222 |
Soft core valve short circuit to the ground |
Check wire and connectors. Check soft core valve. |
Press "Minus" key when fault is removed |
| E223 |
Soft core valve short circuit to the battery |
Check wire and connectors. Check soft core valve. |
Press "Minus" key when fault is removed |
| Baler rotation speed sensor |
| Diagnostic trouble code |
Description |
Solution |
How to clear the code displayed |
| E311 |
Baler rotation speed sensor disconnected |
Check wire and connectors. |
Disappears after 5 seconds |
| E312 |
Baler rotation speed below the minimum value |
Check sensor adjustment. See "Adjusting Baler Rotation Speed Sensor" in "Service" section. Check sensor. See "Channel 017" in this section. |
Disappears after 5 seconds |
| E313 |
Baler rotation speed above the maximum value |
Check sensor adjustment. See "Adjusting Baler Rotation Speed Sensor" in "Service" section. Check sensor. See "Channel 017" in this section. |
Disappears after 5 seconds |
| E601 |
Memory faulty |
Do your personal settings again. |
Disappears after 5 seconds |
| E602 |
Memory faulty |
Check your personal settings. |
Disappears after 5 seconds |
| E603 |
Memory faulty |
See your John Deere dealer. |
Disappears when fault is removed |
| E604 |
Memory faulty |
Check your personal settings. |
Disappears after 5 seconds |
| E605 |
Memory faulty |
See your John Deere dealer. |
Disappears when fault is removed |