Diagnostic Trouble Code List

The diagnostic trouble codes are given in the following table:

Battery
Diagnostic trouble code Description Solution How to clear the code displayed
E001 Voltage drop while actuator is on Check wire and connectors.
Check battery.
Check alternator.
See "Channel 019" in this section.
Press "Minus" key when actuator is off
E002 Battery voltage below 11.2 V Check wire and connectors.
Check battery.
Check alternator.
See "Channel 019" in this section.
Disappears when fault is removed
E003 Battery voltage above 16 V Check alternator.
See "Channel 019" in this section.
Disappears when fault is removed
Bale size potentiometer
Diagnostic trouble code Description Solution How to clear the code displayed
E102 Open circuit or grounded circuit Check wire and connectors.
Check potentiometer.
Press "Minus" key when fault is removed
E103 Shorted circuit Check wire and connectors.
Check potentiometer.
Press "Minus" key when fault is removed
E104 Bale size below minimum Check potentiometer adjustment. See "Channel 005" in this section. Press "Minus" key when fault is removed
E105 Bale size above maximum Check potentiometer adjustment. See "Channel 005" in this section. Press "Minus" key when fault is removed
Right bale shape potentiometer
Diagnostic trouble code Description Solution How to clear the code displayed
E112 Open circuit or grounded circuit Check wire and connectors.
Check potentiometer.
Disappears after 5 seconds
E113 Shorted circuit Check wire and connectors.
Check potentiometer.
Disappears after 5 seconds
E114 Right bale shape below minimum value Check potentiometer adjustment. See "Channel 006" in this section. Disappears after 5 seconds
E115 Right bale shape above maximum value Check potentiometer adjustment. See "Channel 006" in this section. Disappears after 5 seconds

 

OUCC006,0001312 -19-01OCT07-1/6


Left bale shape potentiometer
Diagnostic trouble code Description Solution How to clear the code displayed
E122 Open circuit or grounded circuit Check wire and connectors.
Check potentiometer.
Disappears after 5 seconds
E123 Shorted circuit Check wire and connectors.
Check potentiometer.
Disappears after 5 seconds
E124 Left bale shape below minimum value Check potentiometer adjustment. See "Channel 007" in this section. Disappears after 5 seconds
E125 Left bale shape above maximum value Check potentiometer adjustment. See "Channel 007" in this section. Disappears after 5 seconds
Twine actuator
Diagnostic trouble code Description Solution How to clear the code displayed
E201 Twine actuator disconnected Check wire and connectors. Press "Minus" key when actuator is off
E202 Twine actuator faulty or jammed Check twine actuator. Press "Minus" key when actuator is off
E203 Resistive twine actuator power line Check wire and connectors.
Check twine actuator.
Press "Minus" key when actuator is off
E204 Actuator wire short circuit to the battery Check wire and connectors. Press "Minus" key when fault is removed
E205 Actuator wire short circuit to the ground Check wire and connectors. Press "Minus" key when fault is removed
Net actuator
Diagnostic trouble code Description Solution How to clear the code displayed
E211 Net actuator disconnected Check wire and connectors. Press "Minus" key when actuator is off
E212 Net actuator faulty Check net actuator. Press "Minus" key when actuator is off
E213 Resistive net actuator power line Check wire and connectors.
Check net actuator.
Press "Minus" key when actuator is off
E214 Actuator wire short circuit to the battery Check wire and connectors. Press "Minus" key when fault is removed
E215 Actuator wire short circuit to the ground Check wire and connectors. Press "Minus" key when fault is removed

 

OUCC006,0001312 -19-01OCT07-2/6


Soft core valve
Diagnostic trouble code Description Solution How to clear the code displayed
E221 Soft core valve disconnected Check wire and connectors. Press "Minus" key when fault is removed
E222 Soft core valve short circuit to the ground Check wire and connectors.
Check soft core valve.
Press "Minus" key when fault is removed
E223 Soft core valve short circuit to the battery Check wire and connectors.
Check soft core valve.
Press "Minus" key when fault is removed
Pickup valve (with rotary feeder only)
Diagnostic trouble code Description Solution How to clear the code displayed
E231 Pickup valve disconnected Check wire and connectors. Press "Minus" key when fault is removed
E232 Grounded circuit Check wire and connectors.
Check pickup valve.
Press "Minus" key when fault is removed
E233 Shorted circuit Check wire and connectors.
Check pickup valve.
Press "Minus" key when fault is removed
Knife valve (with precutter only)
Diagnostic trouble code Description Solution How to clear the code displayed
E241 Knife valve disconnected Check wire and connectors. Press "Minus" key when fault is removed
E242 Grounded circuit Check wire and connectors.
Check knife valve.
Press "Minus" key when fault is removed
E243 Shorted circuit Check wire and connectors.
Check knife valve.
Press "Minus" key when fault is removed
Reverser valve (with rotary feeder only)
Diagnostic trouble code Description Solution How to clear the code displayed
E251 Reverser valve disconnected Check wire and connectors. Press "Minus" key when fault is removed
E252 Grounded circuit Check wire and connectors.
Check reverser valve.
Press "Minus" key when fault is removed
E253 Shorted circuit Check wire and connectors.
Check reverser valve.
Press "Minus" key when fault is removed
Cleaning auger rpm sensor
Diagnostic trouble code Description Solution How to clear the code displayed
E304 Chain of cleaning auger broken Check cleaning auger sensor. See "Adjusting Cleaning Auger Sensor" in "Service" section.
Repair cleaning auger drive chain.
Press "Minus" key when fault is removed

 

OUCC006,0001312 -19-01OCT07-3/6


Baler rotation speed sensor
Diagnostic trouble code Description Solution How to clear the code displayed
E311 Baler rotation speed sensor disconnected Check wire and connectors. Disappears after 5 seconds
E312 Baler rotation speed below the minimum value Check sensor adjustment. See "Adjusting Baler Rotation Speed Sensor" in "Service" section.
Check sensor. See "Channel 017" in this section.
Disappears after 5 seconds
E313 Baler rotation speed above the maximum value Check sensor adjustment. See "Adjusting Baler Rotation Speed Sensor" in "Service" section.
Check sensor. See "Channel 017" in this section.
Disappears after 5 seconds
Twine pulley sensor
Diagnostic trouble code Description Solution How to clear the code displayed
E321 Twine coil is empty or twine is not wrapped around the bale Replace twine coil.
Check twine routing. See "Routing Twine Through Guides" in "Preparing the Baler" section.
Check twine pulley sensor adjustment. See "Adjusting Twine Pulley Sensor" in "Service" section.
Press "Minus" key when fault is removed
E322 Twine not cut Check cutter anvil adjustment. See "Adjusting Twine Cutter Anvil" in "Service" section. Press "Minus" key when fault is removed
Net cut switch
Diagnostic trouble code Description Solution How to clear the code displayed
E401 Net cut switch always open Check wire and connectors.
Check net cut switch adjustment. See "Adjusting Net Cut Switch" in "Service" section.
Check net cut switch. See "Channel 012" in this section.
Disappears when fault is removed
E402 Net cut switch always closed Check wire and connectors.
Check net cut switch adjustment. See "Adjusting Net Cut Switch" in "Service" section.
Check net cut switch. See "Channel 012" in this section.
Disappears when fault is removed

 

OUCC006,0001312 -19-01OCT07-4/6


Right gate switch
Diagnostic trouble code Description Solution How to clear the code displayed
E411 Right gate switch always open Check wire and connectors.
Check right gate switch adjustment. See "Adjusting Gate Latch Switch" in "Service" section.
Check right gate switch. See "Channel 014" in this section.
Disappears after 5 seconds
E412 Right gate switch always closed Check wire and connectors.
Check right gate switch adjustment. See "Adjusting Gate Latch Switch" in "Service" section.
Check right gate switch. See "Channel 014" in this section.
Disappears after 5 seconds
Left gate switch
Diagnostic trouble code Description Solution How to clear the code displayed
E421 Left gate switch always open Check wire and connectors.
Check left gate switch adjustment. See "Adjusting Gate Latch Switch" in "Service" section.
Check left gate switch. See "Channel 015" in this section.
Disappears after 5 seconds
E422 Left gate switch always closed Check wire and connectors.
Check left gate switch adjustment. See "Adjusting Gate Latch Switch" in "Service" section.
Check left gate switch. See "Channel 015" in this section.
Disappears after 5 seconds
Oversize bale switch
Diagnostic trouble code Description Solution How to clear the code displayed
E431 Oversize bale switch always open Check wire and connectors.
Check oversize switch adjustment. See "Adjusting Oversize Bale Switch" in "Service" section.
Check oversize bale switch. See "Channel 013" in this section.
Press "Minus" key when fault is removed
E432 Oversize bale switch always closed Check wire and connectors.
Check oversize switch adjustment. See "Adjusting Oversize Bale Switch" in "Service" section.
Check oversize bale switch. See "Channel 013" in this section.
Press "Minus" key when fault is removed

 

OUCC006,0001312 -19-01OCT07-5/6


Positive analog reference
Diagnostic trouble code Description Solution How to clear the code displayed
E512 Grounded circuit Check potentiometer wire and connectors. Press "Minus" key when fault is removed
E513 Shorted circuit Check potentiometer wire and connectors. Press "Minus" key when fault is removed
EPROM
Diagnostic trouble code Description Solution How to clear the code displayed
E601 Memory faulty Do your personal settings again. Disappears after 5 seconds
E602 Memory faulty Check your personal settings. Disappears after 5 seconds
E603 Memory faulty See your John Deere dealer. Disappears when fault is removed
E604 Memory faulty Check your personal settings. Disappears after 5 seconds
E605 Memory faulty See your John Deere dealer. Disappears when fault is removed

 

OUCC006,0001312 -19-01OCT07-6/6