Twine or net tying settings not constant with different sized bales.
|
Lower belt drive roll sensor not connected, defective or not correctly adjusted.
|
Reconnect or readjust sensor. Replace if necessary. See "BaleTrak Monitor Service" and "Service" sections.
|
|
Bale size potentiometer not connected or defective.
|
Reconnect or replace potentiometer. See "BaleTrak Monitor Service" and "Service" sections.
|
No pictograms displayed at LCD screen when switching ON.
|
Monitor not connected.
|
Connect monitor.
|
|
Battery wiring harness not correctly connected.
|
Reconnect properly. See "Preparing the Tractor" section.
|
Erratic monitor functions.
|
Battery charge level too low.
|
Battery should deliver at least 20 A.
|
|
Battery voltage level below 7 V.
|
Monitor requires at least 12 V to function properly. Check or replace tractor battery.
|
|
Battery wiring harness not correctly connected.
|
Reconnect properly. See "Preparing the Tractor" section.
|
Desired bale diameter can not be achieved.
|
Bale size potentiometer not correctly adjusted.
|
Adjust bale size potentiometer. See "Operating BaleTrak Monitor" section.
|
|
Incorrect bale size fine tuning.
|
Proceed to bale size fine tuning. See "BaleTrak Monitor Service" section.
|
|
Monitor not set for baler model.
|
See your John Deere dealer.
|
Oversize alarm at smaller bale size than the maximum.
|
Oversize switch not correctly adjusted.
|
Adjust oversize switch. See "Service" section.
|
|
Monitor not set for baler model.
|
See your John Deere dealer.
|
Soft core solenoid is not power supplied.
|
Tractor PTO driveline is disengaged.
|
Engage tractor PTO driveline.
|