BaleTrak Control Monitor

Symptom Problem Solution

Twine or net tying settings not constant with different sized bales.

Lower belt drive roll sensor not connected, defective or not correctly adjusted.

Reconnect or readjust sensor. Replace if necessary. See "BaleTrak Monitor Service" and "Service" sections.

Bale size potentiometer not connected or defective.

Reconnect or replace potentiometer. See "BaleTrak Monitor Service" and "Service" sections.

No pictograms displayed at LCD screen when switching ON.

Monitor not connected.

Connect monitor.

Battery wiring harness not correctly connected.

Reconnect properly. See "Preparing the Tractor" section.

Erratic monitor functions.

Battery charge level too low.

Battery should deliver at least 20 A.

Battery voltage level below 7 V.

Monitor requires at least 12 V to function properly. Check or replace tractor battery.

Battery wiring harness not correctly connected.

Reconnect properly. See "Preparing the Tractor" section.

Desired bale diameter can not be achieved.

Bale size potentiometer not correctly adjusted.

Adjust bale size potentiometer. See "Operating BaleTrak Monitor" section.

Incorrect bale size fine tuning.

Proceed to bale size fine tuning. See "BaleTrak Monitor Service" section.

Monitor not set for baler model.

See your John Deere dealer.

Oversize alarm at smaller bale size than the maximum.

Oversize switch not correctly adjusted.

Adjust oversize switch. See "Service" section.

Monitor not set for baler model.

See your John Deere dealer.

Soft core solenoid is not power supplied.

Tractor PTO driveline is disengaged.

Engage tractor PTO driveline.

OUCC006,0001334 -19-05OCT07-1/1