As Required: Hydraulic Bale Tensioner Filter

CC2346-UN-06OCT98
A - Filter
B - Cover
C - Cover
Remove covers (B and C) and filter (A) after every 10 days of
operation. Wipe dust off covers and dip filter in petrol to remove
dirt and foreign particles.
In extremely dusty working conditions, clean the covers and
filter more frequently. Reassemble as shown.
When necessary, bleed the hydraulic system by loosening the
hose at hydraulic cylinder. Start tractor and engage power shaft.
The tractor engine must be idling while air is being forced out of
the hose. Tighten hose at hydraulic cylinder after the air has been
forced out.
|
|
OUCC002,00022D4-19-20100331
|
|