Guide Alignment and Clearance

E11961-UN-20SEP88
A - Center Pulley
B - 6.4 ±1.5 mm (0.25 ±0.06 in.)
C - Needle
With needles (C) in highest position, center pulley (A) must
be within 6.4 ±1.5 mm (0.25 ±0.06 in.) (B) in front
of closest point to needle.
Adjust guides by loosening two mounting screws in each guide.
Shift guides to left or right for alignment and forward or rearward
for desired clearance.
Tighten mounting screws.
|
|
OUCC002,000231E-19-20100323
|
|