Diagnostic Trouble Code List

The diagnostic trouble codes are given in the following table:

Battery

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E001

Voltage drop while actuator is ON.

Check wires and connectors.

Check battery.

Check alternator.

See in this section.

Press MINUS key when actuator is OFF.

E002

Battery voltage below 11.2 V.

Check wires and connectors.

Check battery.

Check alternator.

See in this section.

Disappears when problem is resolved.

E003

Battery voltage above 16 V.

Check alternator.

See in this section.

Disappears when problem is resolved.

Bale diameter potentiometer RB311

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E102

Open circuit or grounded circuit.

Check wires and connectors.

Check potentiometer.

Press MINUS key when problem is resolved.

E103

Shorted circuit.

Check wires and connectors.

Check potentiometer.

Press MINUS key when problem is resolved.

E104

Bale diameter below minimum.

Check potentiometer calibration. See or in this section.

Press MINUS key when problem is resolved.

E105

Bale diameter above maximum.

Check potentiometer calibration. See or in this section.

Press MINUS key when problem is resolved.

Right bale shape potentiometer RB322

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E112

Open circuit or grounded circuit.

Check wires and connectors.

Check potentiometer.

Disappears after 5 seconds.

E113

Shorted circuit.

Check wires and connectors.

Check potentiometer.

Disappears after 5 seconds.

E114

Right bale shape below minimum value.

Check potentiometer calibration. See or in this section.

Disappears after 5 seconds.

E115

Right bale shape above maximum value.

Check potentiometer calibration. See or in this section.

Disappears after 5 seconds.

Left bale shape potentiometer RB321

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E122

Open circuit or grounded circuit.

Check wires and connectors.

Check potentiometer.

Disappears after 5 seconds.

E123

Shorted circuit.

Check wires and connectors.

Check potentiometer.

Disappears after 5 seconds.

E124

Left bale shape below minimum value.

Check potentiometer calibration. See or in this section.

Disappears after 5 seconds.

E125

Left bale shape above maximum value.

Check potentiometer calibration. See or in this section.

Disappears after 5 seconds.

Twine actuator MB421

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E201

Twine actuator disconnected.

Check wires and connectors.

Press MINUS key when actuator is OFF.

E202

Twine actuator faulty or jammed.

Check twine actuator.

Press MINUS key when actuator is OFF.

E203

Resistive twine actuator power line.

Check wires and connectors.

Check twine actuator.

Press MINUS key when actuator is OFF.

E204

Actuator wire short circuit to the battery.

Check wires and connectors.

Press MINUS key when problem is resolved.

E205

Actuator wire short circuit to the ground.

Check wires and connectors.

Press MINUS key when problem is resolved.

Net actuator MB411

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E211

Net actuator disconnected.

Check wires and connectors.

Press MINUS key when actuator is OFF.

E212

Net actuator faulty.

Check net actuator.

Press MINUS key when actuator is OFF.

E213

Resistive net actuator power line.

Check wires and connectors.

Check net actuator.

Press MINUS key when actuator is OFF.

E214

Actuator wire short circuit to the battery.

Check wires and connectors.

Press MINUS key when problem is resolved.

E215

Actuator wire short circuit to the ground.

Check wires and connectors.

Press MINUS key when problem is resolved.

Soft core solenoid valve YB351

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E221

Soft core solenoid valve disconnected.

Check wires and connectors.

Press MINUS key when problem is resolved.

E222

Soft core solenoid valve short circuit to the ground.

Check wires and connectors.

Check soft core solenoid valve.

Press MINUS key when problem is resolved.

E223

Soft core solenoid valve short circuit to the battery.

Check wires and connectors.

Check soft core solenoid valve.

Press MINUS key when problem is resolved.

Pickup solenoid valve YB511

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E231

Pickup solenoid valve disconnected.

Check wires and connectors.

Press MINUS key when problem is resolved.

E232

Pickup solenoid valve short circuit to the ground.

Check wires and connectors.

Check pickup solenoid valve.

Press MINUS key when problem is resolved.

E233

Pickup solenoid valve short circuit to the battery.

Check wires and connectors.

Check pickup solenoid valve.

Press MINUS key when problem is resolved.

Precutter knife solenoid valve YB553

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E241

Precutter knife solenoid valve disconnected.

Check wires and connectors.

Press MINUS key when problem is resolved.

E242

Precutter knife solenoid valve short circuit to the ground.

Check wires and connectors.

Check precutter knife solenoid valve.

Press MINUS key when problem is resolved.

E243

Precutter knife solenoid valve short circuit to the battery.

Check wires and connectors.

Check precutter knife solenoid valve.

Press MINUS key when problem is resolved.

Drop floor solenoid valve YB533

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E251

Drop floor solenoid valve disconnected.

Check wires and connectors.

Press MINUS key when problem is resolved.

E252

Drop floor solenoid valve short circuit to the ground.

Check wires and connectors.

Check drop floor solenoid valve.

Press MINUS key when problem is resolved.

E253

Drop floor solenoid valve short circuit to the battery.

Check wires and connectors.

Check drop floor solenoid valve.

Press MINUS key when problem is resolved.

Cleaning auger rpm sensor SB363

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E304

Chain of cleaning auger broken.

Check cleaning auger sensor. See in Service section.

Repair cleaning auger drive chain.

Press MINUS key when problem is resolved.

Baler rotation speed sensor SB362

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E311

Baler rotation speed sensor disconnected.

Check wires and connectors.

Disappears after 5 seconds.

E312

Baler rotation speed below the minimum value.

Check sensor adjustment. See in Service section.

Check sensor. See in this section.

Disappears after 5 seconds.

E313

Baler rotation speed above the maximum value.

Check sensor adjustment. See in Service section.

Check sensor. See in this section.

Disappears after 5 seconds.

Twine pulley sensors SB421 and SB422

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E321

Twine coil is empty or twine is not wrapped around the bale.

Replace twine coil.

Check twine routing. See in Preparing the Baler section.

Check adjustment of twine pulley sensors. See in Service section.

Check sensors. See and in this section.

Press MINUS key when problem is resolved.

E322

Twine not cut.

Check cutter anvil adjustment. See in Service section.

Press MINUS key when problem is resolved.

Net cut switch SB412 or sensor SB414

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E401

Net cut switch or sensor always detects target (net tying rod). No net on bale.

Replace net roll. Check net routing. See in Preparing the Baler section.

Check wires and connectors.

Check net cut switch or sensor adjustment. See or in Service section.

Check net cut switch or sensor. See or in this section.

Disappears when problem is resolved.

E402

Net cut switch or sensor never detects target (net tying rod). Net not cut.

Check net knife and counterknife position. See in Service section.

Check wires and connectors.

Check net cut switch or sensor adjustment. See or in Service section.

Check net cut switch or sensor. See or in this section.

Disappears when problem is resolved.

Right gate latch switch SB334 or sensor SB337

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E411

Right gate latch switch or sensor never detects target. Gate always open.

Check wires and connectors.

Check right gate latch switch or sensor adjustment. See , , or in Service section.

Check right gate latch switch or sensor. See or in this section.

Disappears after 5 seconds.

E412

Right gate latch switch or sensor always detects target. Gate always closed.

Check wires and connectors.

Check right gate latch switch or sensor adjustment. See , , or in Service section.

Check right gate latch switch or sensor. See or in this section.

Disappears after 5 seconds.

Left gate latch switch SB333 or sensor SB336

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E421

Left gate latch switch or sensor never detects target. Gate always open.

Check wires and connectors.

Check left gate latch switch or sensor adjustment. See or in Service section.

Check left gate latch switch or sensor. See or in this section.

Disappears after 5 seconds.

E422

Left gate latch switch or sensor always detects target. Gate always closed.

Check wires and connectors.

Check left gate latch switch or sensor adjustment. See or in Service section.

Check left gate latch switch or sensor. See or in this section.

Disappears after 5 seconds.

Oversize bale switch SB312 or sensor SB317

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E431

Oversize bale switch or sensor never detects target.

Check wires and connectors.

Check oversize switch or sensor adjustment. See , , or in Service section.

Check oversize bale switch or sensor. See or in this section.

Press MINUS key when problem is resolved.

E432

Oversize bale switch or sensor always detects target.

Check wires and connectors.

Check oversize switch or sensor adjustment. See , , or in Service section.

Check oversize bale switch or sensor. See or in this section.

Press MINUS key when problem is resolved.

Positive analog reference

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E512

Grounded circuit.

Check potentiometer wire and connectors.

Press MINUS key when problem is resolved.

E513

Shorted circuit.

Check potentiometer wire and connectors.

Press MINUS key when problem is resolved.

EEPROM

Diagnostic trouble code

Description

Solution

How to clear the code displayed

E601

Memory faulty.

Do your personal settings again.

Disappears after 5 seconds.

E602

Memory faulty.

Check your personal settings.

Disappears after 5 seconds.

E603

Memory faulty.

See your John Deere dealer.

Disappears when problem is resolved.

E604

Memory faulty.

Check your personal settings.

Disappears after 5 seconds.

E605

Memory faulty.

See your John Deere dealer.

Disappears when problem is resolved.

OUCC006,0001A45-19-20130305