Washing Element

First rinse the filter element under running water to remove as much dirt as possible.

Then soak element for 15 minutes in lukewarm water, not above 32°C (90°F). If necessary, add a non-alkaline household detergent and wash filter.

Rinse filter element in clean running water with a pressure not exceeding 200 kPa (2 bar; 30 psi). Allow filter element to dry.

IMPORTANT: Never wash element in fuel or a strong cleaning agent. Change both primary and secondary air cleaner elements at least every 1200 operating hours.

RW6823