| Step |
Action |
GO TO: |
| Prepare Header for Calibration. |
Hook up header to the combine. Move the machine onto a level concrete surface. |
GO TO Step 1. |
| 1 - Select Diagnostic Mode |
The cornerpost tach is used to provide diagnostic mode. While pressing the up/down button on the tach, turn the combine key switch "ON" and start the combine. The tach should display: -- dIA |
OK: GO TO Step 2. NOT OK: Check cornerpost tach. |
| 2 - Select AHC |
Press the up/down button on the tach to obtain the "AHC" display. The tach should display: -- AHC |
OK: GO TO Step 3. NOT OK: GO TO AHC Test Procedure No. 3. |
| 3 - Enter float calibration mode. |
Press the fan speed button on the tach to access the "AHC" diagnostic mode. The tach should display: 0000 AHC Press the up/down button on the tach twice to obtain mode 2. The tach should display: 0002 AHC Press the fan speed button on the tach to jump to header calibration mode 30. Then press the tach up/down button to obtain the float calibration mode 31. The tach should display: 0031 FLO |
OK: GO TO Step 4. NOT OK: Check tach. |
| 4 - Calibrate float system. |
With the raise/lower rocker switch on the multifunction lever, lower the header until it is about 100 mm above ground level (the header must not touch the ground). Press the fan speed button on the tach. The tach should display: 0031 HFL Press the resume to float button on the multifunction lever. The tach should display: 0031 EOC |
OK: GO TO Step 5. NOT OK: Header does not raise or lower, check system hydraulics. NOT OK: Display does not change to "HFL", make sure raise/lower rocker switch is off. See Test Procedure No. 8. NOT OK: Display "E5X" or "E39" indicates an error. GO TO Test Procedure No. 37. NOT OK: Display does not change from "HFL". GO TO Test Procedure No. 23. |