| ERROR CODE |
DESCRIPTION OF ERROR |
CORRECTIVE ACTION |
| E02 |
Header calibration cannot be done with this type of header |
Check header type, Mode No. 32. |
| E11 |
Height setting pot voltage less than 0.5 V. |
Go to Test Procedure No. 10 |
| E12 |
Height setting pot voltage greater than 4.5 V. |
Go to Test Procedure No. 10 |
| E13 |
Height setting pot voltage going in the wrong direction. |
Repeat calibration moving pot constantly in the correct direction. If error reappears then go to Test Procedure No. 10. |
| E14 |
Height setting pot voltage range less than 2.0 V. |
Go to Test Procedure No. 10 |
| E21 |
Float setting pot voltage less than 0.5 V. |
Go to Test Procedure No. 11 |
| E22 |
Float setting pot voltage greater than 4.5 V. |
Go to Test Procedure No. 11 |
| E23 |
Float setting pot voltage going in the wrong direction. |
Repeat calibration moving pot constantly in the correct direction. If error reappears then go to Test Procedure No. 11. |
| E24 |
Float setting pot voltage range less than 2.0 V. |
Go to Test Procedure No. 11 |
| E39 |
Pressure sensor voltage reading less than 1.0 V (30 bar). |
Go to Test Procedure No. 16 |
| E51 |
Feeder house angle pot voltage less than 0.25 V. |
Go to Test Procedure No. 13 |
| E52 |
Feeder house angle pot voltage greater than 4.75 V. |
Go to Test Procedure No. 13 |
| E53 |
Feeder house angle pot voltage going in the wrong direction. |
Repeat calibration moving feeder house constantly in the correct direction. If error reappears then go to Test Procedure No. 13. |
| E54 |
Feeder house angle pot voltage range less than 2.0 V. |
Go to Test Procedure No. 13 |
| E55 |
Feeder house angle pot lower voltage greater than 2.5 V. |
Go to Test Procedure No. 13 |
| E56 |
Feeder house angle pot upper voltage less than 2.5 V. |
Go to Test Procedure No. 13 |
| E71 |
Left height sensor voltage less than 0.25 V. |
Go to Test Procedure No. 14 |
| E72 |
Left height sensor voltage greater than 4.75 V. |
Go to Test Procedure No. 14 |
| E73 |
Left height sensor voltage going in the wrong direction. |
Repeat calibration. If error reappears then go to Test Procedure No. 14. |
| E74 |
Left height sensor voltage range less than 2.0 V. |
Go to Test Procedure No. 14 |
| E75 |
Left height sensor lower voltage greater than 2.5 V. |
Go to Test Procedure No. 14 |
| E76 |
Left height sensor upper voltage less than 2.5 V. |
Go to Test Procedure No. 14 |
| E81 |
Right height sensor voltage less than 0.25 V. |
Go to Test Procedure No. 15 |
| E82 |
Right height sensor voltage greater than 4.75 V. |
Go to Test Procedure No. 15 |
| ERROR CODE |
DESCRIPTION OF ERROR |
CORRECTIVE ACTION |
| E83 |
Right height sensor voltage going in the wrong direction. |
Repeat calibration. If error reappears then go to Test Procedure No. 15. |
| E84 |
Right height sensor voltage range less than 2.0 V. |
Go to Test Procedure No. 15 |
| E85 |
Right height sensor lower voltage greater than 2.5 V. |
Go to Test Procedure No. 15 |
| E86 |
Right height sensor upper voltage less than 2.5 V. |
Go to Test Procedure No. 15 |
| E91 |
Flex head height sensor voltage less than 0.25 V. |
Go to Test Procedure No. 21 |
| E92 |
Flex head height sensor voltage greater than 4.75 V. |
Go to Test Procedure No. 21 |
| E93 |
Flex head height sensor voltage going in the wrong direction. |
Repeat calibration. If error reappears then go to Test Procedure No. 21. |
| E94 |
Flex head height sensor voltage range less than 2.0 V. |
Go to Test Procedure No. 21 |
| E95 |
Flex head height sensor lower voltage greater than 2.5 V. |
Go to Test Procedure No. 21 |
| E96 |
Flex head height sensor upper voltage less than 2.5 V. |
Go to Test Procedure No. 21 |