| Display Address / Test Procedure |
Circuit Description |
Display / Specification |
RELATED FAULT CODE |
| 1 |
Recall codes / Clear codes |
Mode Nos. 3 - 23 |
all |
| 2 |
Global intermittent circuit mode |
Modes numbers 3 -23 |
none |
| 3 |
Battery voltage to logic circuit |
12.3 - 13.5 volts (normal) |
none |
| 4 |
Battery voltage to valves |
12.3 - 13.5 volts (normal) |
none |
| 5 |
Battery voltage to valves |
12,3 - 13.5 volts (normal) |
none |
| 6 |
Sensor power (600 Series and Rigid) |
4.8 - 5.2 volts |
218 |
| 7 |
Flex pad #5 voltage (300 Series Flex) |
0.0 - 5.0 volts |
none |
| 8 |
Manual Reel, Tilt and Raise/Lower rocker switch status |
Code: xxx0 - R/L Switch "OFF" xxx1 - Slow Raise xxx2 - Slow Lower xxx3 - Fast Raise xxx4 - Fast Lower xxx5 - R/L Switch Error xx0x - Tilt Switch Off xx1x - Tilt Left xx2x - Tilt Right. xx5x - Tilt Switch Error x0xx - Reel R/L Off x1xx - Reel Raise x2xx - Reel Lower x5xx - Reel R/L Error 0xxx - Reel F/A Off 1xxx - Reel Fore 2xxx - Reel Aft 5xxx - Reel F/A Error |
232, 233, 235, 236 |
| 9 |
Manual flex pressure increase/decrease switch status (600 Series) |
0000 - Pressure "OFF" 0001 - Pressure Increase 0002 - Pressure Decrease 0005 - Switch Error |
234 |
| 10 |
Height control setting (Rigid) |
0.50 - 4.50 volts |
220 |
| 11 |
Float control setting (Rigid) |
0.50 - 4.50 volts |
221 |
| 12 |
Flex pad #6 voltage (300 Series Flex) |
0.0 - 5.0 volts |
none |
| 13 |
Feeder house angle sensor (Rigid) |
0.25 - 4.75 volts |
224 |
| 14 |
Left header height sensor (600 Series) Right header height sensor (300 Series Flex) |
0.25 - 4.75 volts (600 Series) 0.0 - 5.0 volts (300 Series Flex) |
225 (600 Series) none (300 Series Flex) |
| 15 |
Right header height sensor (600 Series) Left header height sensor (300 Series Flex) |
0.25 - 4.75 volts (600 Series) 0.0 - 5.0 volts (300 Series Flex) |
226 (600 Series) none (300 Series Flex) |
| Display Address / Test Procedure |
Circuit Description |
Display / Specification |
RELATED FAULT CODE |
| 16 |
Lift cylinder pressure sensor (Rigid) |
0.24 - 4.76 volts |
227 |
| 17 |
Header height sensor # 2 |
0.0 - 5.0 volts |
none |
| 18 |
Header height sensor # 3 |
0.0 - 5.0 volts |
none |
| 19 |
Reel raise/lower position |
0.50 - 4.50 volts |
241 |
| 20 |
Reel fore/aft position (Not Used) |
0.50 - 4.50 volts |
242 |
| 21 |
Flex head height sensor (600 Series) Volt sensor # 1 (300 Series Flex) |
0.25 - 4.75 volts (600 Series) 0.0 - 5.0 volts (300 Series Flex) |
240 (600 Series) none (300 Series Flex) |
| 22 |
Resume switch positions |
Code: 0000 - all off 0xx1 - resume float 0x1x - resume height 01xx - auto enable |
none |
| 23 |
Float, tilt, height, and reel enable switch positions |
Code: 0000 - all "OFF" xxx1 - reel on xx1x - height on x1xx - tilt on 1xxx - reel "ON" |
none |
| 23 (Only for 300 Series) |
Float, tilt, height, and reel enable switch positions |
xx1x - Pos 1 xx2x - Pos 2 xx3x - Pos 3 |
none |
| 24 |
Accumulator shutoff and flex pressure diverter valve status |
Code: 00x0 - accum valve off 00x1 - accum valve on 000x - diverter valve off 001x - diverter valve on |
215, 216 |
| 25 |
Height Valve Command |
Code: 0000 - Valve off 0001 - Slow raise command 0002 - Slow lower command 0003 - Fast raise command 0004 - Fast lower command - - - - - Valve disabled |
209, 210, 211, 212 |
| 26 |
Reel, Tilt, and Unload Valve Commands |
Code: 0000 - all off xxx1 - unloading valve on xx1x - tilt left xx2x - tilt right x1xx - reel raise x2xx - reel lower 1xxx - reel fore 2xxx - reel aft |
217, 213, 214 |
| 27 |
Flex Pressure, Tilt and Height Operating Modes |
Code: 0xxx - 5xxx pressure modes x0xx - x6xx tilt modes xx00 - xx17 height modes |
none |