Fan Alarm Adjustment

With engine running, engage separator.

Press key (A) to display fan speed. Continue to press key (A) (for approx. 2 seconds) until the last digit of the displayed speed turns into an "A". Now alarm trigger threshold is 75% of the displayed speed.

If fan speed drops below alarm speed during operation, the fan speed indicator light will glow and a continuous warning signal will be heard.

ZX014269

AG,CO03622,1449 -19-20AUG04-1/1