Low Shaft Speed Monitoring System - Protected Components

CQ203981


A-Straw chopper
B-Tailings elevator


C-Straw walker
D-Clean grain elevator


E-Fan
F-Threshing cylinder


G-Power Separator (WTS)

AG,CO03622,1451 -19-20AUG04-1/3


In the event of a malfunction, the low shaft speed monitoring system activates the right-hand corner post indicator lights and an intermittent acoustic warning signal.

With the engine shut off, electrical circuitry on and the separator engaged, all five or six indicator lights must glow and the warning signal must keep mute. With the engine running (at fast idle) and the separator

engaged, all indicator lights should go out and the warning signal must remain mute.

NOTE: Reset the Infotrak monitor alarm threshold every time the threshing cylinder and/or fan speed are altered.

The other shafts are adjusted in the factory to pre-set speeds.

AG,CO03622,1451 -19-20AUG04-2/3


It is possible to reprogram them using the following procedure:

1. With the engine running and the threshing engaged, set engine to maximum rpm.
2. Press switches (A) and (B) on the multifunction control handle simultaneously for 3 seconds. An intermittent warning signal will sound 3 times and the indicator lights will also glow 3 times. When this happens the 5 shafts will be reprogrammed for their new settings.
3. To return to factory standard settings, press the two switches for 6 seconds. Confirmation is provided by an intermittent warning signal that will sound 6 times and the indicator lights will also glow 6 times.

CQ216450


A-Cutting Position/ Return to Cut
B-Break Off Cut/Floating

AG,CO03622,1451 -19-20AUG04-3/3