Operational Adjustment of Harvest Performance Monitor sensors

CQ191882

The amplification of the sensors signal is preselected in the cab at the adjusting/selecting unit of harvest performance monitor (A).

Adjustment of cleaning shoe and straw walker sensor sensitivity:

X - Greater sensor sensitivity - For finer grain crops

Y - Medium sensor sensitivity - for medium grain crops (covers a wide range of standard crops).

Z - Lower sensor sensitivity - for coarse grain crops.

NOTE: Always leave the sieve and straw walker sensors at a medium setting.

AG,CO03622,1457 -19-30JUL04-1/1