Reel Speed Control Switch (DIAL-A-SPEED™)

Reel speed-to-ground speed ratio may be preselected. Turning switch (A) clockwise alters ratio from 0.8 to 2.2 (shown on switch as 1 to 11). Turning switch all the way counterclockwise deactivates reel speed control system.

NOTE: Reel speed control system will only operate within a ground speed range from 1.2 km/h (0.75 mph) to approx. 10 km/h (6.25 mph).


I-Reel speed control off
II-Switch position for diagnosis/manual reel speed (refer to "Service-Electrical System")
III-Reel speed is 2.2 times faster than ground speed

CQ194570

DIAL-A-SPEED is a trademark of Deere & Company

AG,CO03622,1550 -19-30AUG04-1/2


NOTE: For tracked combines there is a large difference between the combine turnover speed and reel speed. Therefore, the combine ground speed can be disregarded when the DIAL-A-SPEED system is engaged.

Operation:

During operation, reel speed may be adapted to harvesting conditions.

When working in down and tangled grain crops and a reel speed faster than ground speed is desired, move switch (A) to area (X) (for a ratio of between 1.1 and 2.2; shown on switch as 3-11).

NOTE: With reel speed control system activated, the reel will continue to rotate at the slowest speed when ground speed drops below operating range.

CQ194580

AG,CO03622,1550 -19-30AUG04-2/2