"QUICK STOP" Switch

IMPORTANT: Header, reverser and unloading auger drives can be disengaged instantaneously with this switch in the event of malfunctions.

The reel will be also disengaged when the quick stop switch is activated.

To re-engage any one of the functions, turn the corresponding switch OFF and ON. Before doing so, make sure that the malfunction has been corrected.

ZX009162

"QUICK STOP" Switch and Header Switch

CQ203510

Unloading Auger Drive Switch

CQ216420

Engaging reverser

AG,CO03622,1651 -19-19NOV02-1/1