Remove pivot arm (A) and bolt (B) on both sides of yoke (C).
Remove snap ring (D) and take out flange (E) with bearing (F).
Remove belt (G) from the lower fan drive unit. Pull belt (G) over outer variable pulley (H) and yoke (C). The belt comes out over the bearing support opening (I). Pull the belt out through the opening.
To install a new belt follow this procedure in reverse order.
NOTE:
Make sure the upper pulley lugs are correctly connected. Firstly install the belt on the upper unit.
A-Pivot Arm
B-Locking Bolt
C-Yoke
D-Snap Ring
E-Bearing Support Flange
F-Bearing
G-Drive Belt
H-Outer Variable Pulley
I-Bearing Housing
|