IMPORTANT:
Before carrying out service of any kind on the electrical system, always disconnect the ground cable, since this prevents damage from occurring.
If the starting motor does not function or operates only sluggishly, the fault may lie not in the starting motor but in one of the causes suggested below.
-
Loose, dirty or corroded connections:
Clean and tighten all connections.
-
Low battery output:
Check electrolyte level and specific gravity of battery. If necessary, recharge battery. See "Battery Electrolyte Level".
-
Run down battery:
Recharge battery.
|
-
Engine oil with incorrect viscosity:
Use oil with specified viscosity.
-
Low environmental temperature (Europe and United States):
An intake heating system is automatically engaged by the ECU to increase intake manifold air temperature to improve cold starting. An indicator light goes out when it is possible to turn starter key.
-
Defective starting motor safety relay:
Replace relay.
If the suggested remedies fail to improve starting motor operation, see your local John Deere dealer. Have starting motor inspected by a specialist workshop once every year.
|