Error Codes, INFOTRAK Monitor

Whenever the INFO-TRAK™ monitor displays a three-digit number followed by an "E", a malfunction or operating error is indicated. The cause of equipment malfunction may be a broken wire etc.

IMPORTANT: If the solution cannot be found or the malfunction solved, see your John Deere dealer.

Error Codes Problem Solution
101E Counter of engine operating hours on INFOTRAK monitor is defective.  
102E Working hour counter of INFO-TRAK monitor is defective  
122E Concave cannot be adjusted, sensor signals not in correct area (too low) Check fuse (F27)
123E Concave cannot be adjusted, sensor signals not in correct area (too high) Check fuse (F27)
128E No reaction from INFO-TRAK monitor  
129E    
130E Adjustment motor cannot reduce fan speed to the desired rpm Check fuses (F8, F30)
131E Variator cannot reduce cylinder speed to the desired rpm Check fuse (F8)
132E Adjustment motor cannot reduce concave clearance to desired gap Check fuse (F27)
135E Adjustment motor cannot increase fan speed to the desired rpm Check fuses (F8, F30)
136E Variator cannot increase cylinder speed to the desired rpm Check fuse (F8)
137E Adjustment motor cannot increase concave clearance to desired gap Check fuse (F27)
139E With versions 7 or 9 of EPROM Engine speed at "automatic machine adjustment" is less than 2000 rpm, or the separator is switched off

 

AG,CO03622,2225 -19-26JUL04-1/1