Automatic Header Control System Error Codes

IMPORTANT: The solution number for the error message is the number (step) of the header test procedure.

Error Codes Error Message Solution
200 System not calibrated  
201 Header height not calibrated  
202 Header float not calibrated  
203 Header height sensors not available 28
209 Slow raise valve driver circuit fault 25
210 Slow lower valve driver circuit fault 25
211 Fast raise valve driver circuit fault 25
212 Fast lower valve driver circuit fault 25
213 Tilt left valve driver circuit fault 26
214 Tilt right valve driver circuit fault 26
215 Flex pressure diverter valve circuit fault 24
216 Accumulator shutoff valve circuit fault 24
218 Sensor power fault 6
220 Height control setting fault 10
221 Float control setting fault 11
224 Feeder house angle sensor fault 13
225 Header height sensor (left) fault 14
226 Header height sensor (right) fault 15
227 Cylinder pressure sensor fault 16
232 Header raise/lower switch fault 8
233 Manual tilt switch fault 8
234 Flex pressure switch fault. 9
235 Reel raise/lower switch fault 8
236 Reel forward switch fault 8
240 Header height sensor fault 21
241 Reel raise/lower position sensor fault (not available) 19
242 Reel forward position sensor fault (not available) 20
243 Reel fast raise valve driver circuit fault 26
244 Reel fast lower valve driver circuit fault 26
245 Reel forward position circuit fault 26
246 Reel aft position circuit fault 26
247 Reel raise/lower setpoint position not reached (not available)  
248 Reel fore/aft setpoint position not reached (not available)  

 

AG,CO03622,2229 -19-26JUL04-1/1