ERROR CODE 0 -Light off X - Light on |
PROBLEM |
SOLUTION |
A - 0 B - 0 C - 0 D - 0 |
No power |
Check fuse (F23) |
A - X B - 0 C - 0 D - 0 |
No ground speed signal |
Check 3-speed transmission signal transmitting unit |
A - 0 B - X C - 0 D - 0 |
Ground speed signal outside of operating range |
See "Reel Speed Control System Operating Range " in the operator's manual. |
A - X B - X C - 0 D - 0 |
No reel speed signal |
Check header signal transmitting unit |
A - 0 B - 0 C - X D - 0 |
Reel speed signal outside of operating range |
|
A - X B - 0 C - X D - 0 |
Error "Bit 1" of reel speed control switch |
Check reel speed control switch, electrical board and harness |
A - 0 B - X C - X D - 0 |
Error "Bit 2" of reel speed control switch |
Check reel speed control switch, electrical board and harness |
A - X B - X C - X D - 0 |
Error "Bit 4" of reel speed control switch |
Check reel speed control switch, electrical board and harness |
A - 0 B - 0 C - 0 D - X |
Error "Bit 8" of reel speed control switch |
Check reel speed control switch, electrical board and harness |
A - X B - 0 C - 0 D - X |
Option A, input short circuiting to ground |
|
ERROR CODE 0 -Light off X - Light on |
PROBLEM |
SOLUTION |
A - 0 B - X C - 0 D - X |
Option A, input 2 short circuiting to ground |
|
A - X B - X C - 0 D - X |
Reel does not accelerate |
Check electrical board, cut wire or hydraulic motor |
A - 0 B - 0 C - X D - X |
Reel does not reduce speed |
Check electrical board, cut wire or hydraulic motor |
A - X B - 0 C - X D - X |
Reel speed control switch outside of diagnostic mode position |
See "Reel Speed Control System Operating Range " in the operator's manual. |
A - 0 B - X C - X D - X |
No problem found |
|
A - X B - X C - X D - X |
All contacts of reel speed control switch open |
|