| Display Addresses |
Circuit Description |
Display / Description |
RELATED FAULT CODE |
| 1 |
Recover codes / Delete codes |
Mode 3 to mode 23 numbers |
all |
| 2 |
Global intermittent circuit mode (bip) |
Mode 3 to mode 23 numbers |
none |
| 3 |
Battery voltage for logic circuit and valves (F28) |
12.3 - 13.5 Volts (normal) |
none |
| 4 |
Battery voltage for valves (F15) |
12.3 - 13.5 Volts (normal) |
none |
| 5 |
Battery voltage for valves (F14) |
12.3 - 13.5 Volts (normal) |
none |
| 6 |
Sensor power |
4.8 - 5.2 Volts |
218 |
| 7 |
Voltage of height sensor number 5 contact (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 8 |
Status of Reel Manual Control two position switch, Tilt and Raise/Lower |
Code: xxx0 - Left/Right Switch "OFF" xxx1 - Slow Raise xxx2 - Slow Lower xxx3 - Fast Raise xxx4 - Fast Lower xxx5 - Raise/Lower Switch Error
xx0x - Tilt Switch "OFF" xx1x - Left Tilt xx2x - Right Tilt xx5x - Tilt Switch Error
x0xx - Right/Left Reel "OFF" x1xx - Raising Reel x2xx - Lowering Reel x5xx - Right/Left Reel Error
0xxx - Reel Fore/Aft Position "OFF" 1xxx - Reel Forward Position 2xxx - Reel Aft Position 5xxx - Reel Fore/Aft Position Error |
232, 233, 235, 236 |
| 9 |
Status of manual flex pressure raise/lower switch (Flex 600 Series) |
0000 - Pressure "OFF" 0001 - Pressure Increase 0002 - Pressure Decrease 0005 - Switch Error |
234 |
| 10 |
Height control setting (Rigid) |
0.50 - 4.50 Volts |
220 |
| 11 |
Float control setting (Rigid) |
0.50 - 4.50 Volts |
221 |
| 12 |
Voltage of height sensor number 6 contact (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 13 |
Feeder house angle sensor (Rigid) |
0.25 - 4.75 Volts |
224 |
| 14 |
Left-hand header tilt sensor (Flex 600 Series) |
0.25 - 4.75 Volts |
225 |
| Display Addresses |
Circuit Description |
Display / Description |
RELATED FAULT CODE |
| 14 |
Right-hand header tilt sensor (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 15 |
Right-hand header tilt sensor (Flex 600 Series) |
0.25 - 4.75 Volts |
226 |
| 15 |
Left-hand header tilt sensor (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 16 |
Lift cylinder pressure sensor (Rigid) |
0.24 - 4.76 Volts |
227 |
| 17 |
Voltage of height sensor number 2 contact (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 18 |
Voltage of height sensor number 3 contact (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 19 |
Reel raise/lower position sensor (Flex 600 Series) |
0.25 - 4.75 Volts |
241 |
| 20 |
Reel fore/aft position sensor (Flex 600 Series) |
0.25 - 4.75 Volts |
242 |
| 21 |
Flex header height sensor (Flex 600 Series) |
0.25 - 4.75 Volts |
240 |
| 21 |
Voltage of height sensor number 1 contact (Flex 300 Series) |
0.0 - 5.0 Volts |
none |
| 22 |
Resume switch positions |
Code: 0000 - Switches "OFF" 0xx1 - Resume Float 0x1x - Return to cut 01xx - Auto Enable |
none |
| 23 |
Reel, float, tilt and height enable switch positions |
Code: 0000 - Switches "OFF" xxx1 - Float "ON" xx1x - Height "ON" x1xx - Tilt "ON" 1xxx - Reel "ON" |
none |
| 23 |
Height switch positions (Flex 300 Series) |
xx1x - Pos 1 xx2x - Pos 2 xx3x - Pos 3 |
none |
| 24 |
Status of flex pressure divert valve and accumulator shut-off safety valve |
Code: 00x0 - Accumulator valve "OFF" 00x1 - Accumulator valve "ON" 000x - Divert Valve "OFF" 001x - Divert Valve "ON" |
215, 216 |
| 25 |
Height valve control block |
Code: 0000 - Valve "OFF" 0001 - Slow Raise Command 0002 - Slow Lower Command 0003 - Fast Raise Command 0004 - Fast Lower Command - - - - - Disabled Valve |
209, 210, 211, 212 |
| Display Addresses |
Circuit Description |
Display / Description |
RELATED FAULT CODE |
| 26 |
Overflow valve, tilt and reel control blocks |
Code: 0000 - All "OFF" xxx1 - Overflow Valve "ON" xx1x - Left Tilt xx2x - Right Tilt x1xx - Raising Reel x2xx - Lowering Reel 1xxx - Reel Forward Position 2xxx - Reel aft position |
213, 214, 243, 244, 245, 246 |
| 27 |
Flex pressure, tilt and height operating modes |
Code: 0xxx - 5xxx Pressure Modes x0xx - x6xx Tilt Modes xx00 - xx17 Height Modes |
none |
| 28 |
Header sensors, reel operating modes |
Code: 1xxx - Mean Height Sensor x1xx - Mechanical Height Sensors xx0x - xx7x Reel Fore/Aft Position Modes xxx0 - xxx7 Reel Raise/Lower Position Modes |
none |
| 29 |
Error cancel modes |
Code: 0 - 2048 |
none |
| 30 |
Header calibration mode (Corn Header and 600 Series) |
|
none |
| 31 |
Float calibration mode (Rigid) |
|
none |
| 32 |
Header type |
0 - 300 Series Flex Headers 1 - 600 Series Flex Headers 2 - 300 and 600 Series Rigid Header 3 - Corn Header |
none |
| 33 |
Synchronized raise valve |
0 - 5 seconds (3 second standard) |
none |
| 34 |
Height set point (Corn Header and 600 Series Flex Header) |
0 - 250 (standard: 35) |
none |
| 35 |
Height system deadband (Corn Header and 600 Series Header) |
50 - 250 (standard: 105) |
none |
| 36 |
Tilt system deadband (Corn Header and 600 Series Header) |
50 - 250 (standard: 150) |
none |
| 37 |
Fast Raise of Flex Header (Flex 300 Series) |
0 - 1 |
none |
| 38 |
TEST ONLY - no display AHC calibration fault codes (600 Series) |
|
none |
| 39 |
TEST ONLY - no display Calibration memory fault |
|
200 |
| 40 |
TEST ONLY - no display Header height calibration fault |
|
201 |
| 41 |
TEST ONLY - no display Header float calibration fault |
|
202 |