Header AHC Calibration Procedure for 600 Series-Step by Step

Step Action GO TO:
Prepare Header for Calibration Hook up header to the combine and ensure header harness is connected to main vehicle harness. Check that the header height sensors are in working order.
Move the machine onto a level concrete surface.
GO TO Step 1
1 - Select Diagnostic Mode The INFO-TRAK™ monitor is used for diagnostic mode. Press the up/down key on the INFO-TRAK monitor, turn the combine starter key on and start the combine.
The display should indicate:
- -
dlA
OK: GO TO step 2
NOT OK: Check INFO-TRAK Monitor
2 - Select AHC Press the up/down key on the Infotrak until "AHC" is displayed.
The display should indicate:
- -
AHC
OK: GO TO step 3
NOT OK: See your nearest dealer
3 - Enter header calibration mode Press the fan speed key on the INFO-TRAK monitor to access the "AHC" diagnostic mode
The display should indicate:
0000
AHC
Press the up/down key on the INFO-TRAK monitor twice to obtain mode 2.
The display should indicate:
0002
AHC
Press the fan speed key on the INFO-TRAK monitor to obtain header calibration mode 30
The display should indicate:
0030
Hdr
OK: GO TO step 4
NOT OK: Check INFO-TRAK Monitor
4 - Calibrate height system and return-to-cut system. Establish minimum sensor settings With the raise/lower rocker switch on the multifunction lever handle, lower the header until it rests fully on the ground.
The left and right sides of the header should come into contact with the ground at the same time as the header is lowered. Press the fan speed key on the INFO-TRAK monitor.
The display should indicate:
0030
H - d
Press the return to cut knob on the multifunction control handle.
The display should indicate:
0030
H - U
OK: GO TO step 5
NOT OK: Header does not raise or lower, check system hydraulics
NOT OK: Display does not change to "H-U", make sure raise/lower rocker switch is off. See your nearest dealer.
NOT OK: Display shows "E5X", "E7X", "E8X" or "E9X", indicating an error. See your nearest dealer
NOT OK: Display does not change from "r - d". See your nearest dealer

 

ML70882,00004BA -19-26JUL04-1/2


Step Action GO TO:
5 - Establish maximum sensor settings. With the raise/lower rocker switch on the multifunction lever handle, raise the header until it reaches its limit. Press and hold the return to cut knob on the multifunction control handle.
The display should indicate:
0030
EOC
OK: GO TO step 6
NOT OK: Display shows "E5X", "E7X", "E8X" or "E9X", indicating an error.
See your nearest dealer
6 - Store header calibration data in the AHC. Press the fan speed knob on the INFO-TRAK monitor to store all calibration values. If no errors occurred during calibration, the following will be displayed:
EOC
E00
END
If any errors occurred during calibration, previous calibration values are kept and the following will be displayed:
EOC
Err
END
OK: Calibration is done. GO TO step 7
NOT OK: See your nearest dealer
7 -
Reset to normal operation.
The starter key must be turned to the OFF position to return the AHC to normal operation at the next start-up.  

 