300 and 600-CWS/WTS Series Rigid Header Float Calibration Procedure

The pressure sensor is calibrated for the header floatation installed on the combine by means of the float system calibration procedure. If float mode is used, then the float calibration procedure must be performed when a header is initially hooked up.

The following is a step by step procedure that shows operator action and system response.

ML70882,00004BB -19-26JUL04-1/3


Step Action GO TO:
Prepare Header for Calibration. Hook up header to the combine. Move the machine onto a level concrete surface. GO TO Step 1.
1 - Select Diagnostic Mode The INFO-TRAK™ monitor is used to provide diagnostic mode.
While pressing the up/down key on the INFO-TRAK, turn the starter key to the "ON" position and start up the combine.
The display should indicate:
--
dIA
OK: GO TO step 2
NOT OK: Check INFO-TRAK Monitor
2 - Select AHC Press the up/down key on the Infotrak until "AHC" is displayed.
The display should indicate:
--
AHC
OK: GO TO step 3
NOT OK: See your nearest dealer
3 - Enter float calibration mode. Press the fan speed key on the INFO-TRAK monitor to access the "AHC" diagnostic mode
The display should indicate:
0000
AHC
Press the up/down key on the INFO-TRAK monitor twice to obtain mode 2.
The display should indicate:
0002
AHC
Press the fan speed key on the INFO-TRAK monitor to obtain header calibration mode 30. Then press the up/down key to obtain float calibration mode 31.
The display should indicate:
0031
FLO
OK: GO TO step 4
NOT OK: Check INFO-TRAK Monitor
4 - Calibrate float system. With the raise/lower rocker switch on the multifunction control handle, lower the header until it is about 100 mm above ground level (the header must not touch the ground).
Press the fan speed knob on the INFO-TRAK monitor. The display indicates:
0031
HFL
Press the resume to float knob on the multifunction control handle.
The display should indicate:
0031
EOC
OK: GO TO step 5
NOT OK: Header does not raise or lower, check system hydraulics
NOT OK: Display does not change to "HFL", make sure header raise/lower rocker switch is off.
See your nearest dealer
NOT OK: "E5X" or "E39" on display indicates an error. See your nearest dealer
NOT OK: The display does not change, continuously shows "HFL". See your nearest dealer

 

ML70882,00004BB -19-26JUL04-2/3


Step Action GO TO:
5 Store header calibration data in the AHC. Press the fan speed knob on the INFO-TRAK monitor to store all calibration values.
If no errors occurred during calibration, the following will be displayed:
EOC
E00
END
If any errors occurred during calibration, previous calibration values are kept and the following will be displayed:
EOC
Err
END
OK: Calibration is done. GO TO step 6.
NOT OK: See your nearest dealer
6 - Reset to normal operation. The starter key must be turned OFF to return the AHC to normal operation on next start-up.  

 

ML70882,00004BB -19-26JUL04-3/3