| Step |
Action |
GO TO: |
| Prepare Header for Calibration. |
Hook up header to the combine. Move the machine onto a level concrete surface. |
GO TO Step 1. |
| 1 - Select Diagnostic Mode |
The INFO-TRAK™ monitor is used to provide diagnostic mode. While pressing the up/down key on the INFO-TRAK, turn the starter key to the "ON" position and start up the combine. The display should indicate: -- dIA |
OK: GO TO step 2 NOT OK: Check INFO-TRAK Monitor |
| 2 - Select AHC |
Press the up/down key on the Infotrak until "AHC" is displayed. The display should indicate: -- AHC |
OK: GO TO step 3 NOT OK: See your nearest dealer |
| 3 - Enter float calibration mode. |
Press the fan speed key on the INFO-TRAK monitor to access the "AHC" diagnostic mode The display should indicate: 0000 AHC Press the up/down key on the INFO-TRAK monitor twice to obtain mode 2. The display should indicate: 0002 AHC Press the fan speed key on the INFO-TRAK monitor to obtain header calibration mode 30. Then press the up/down key to obtain float calibration mode 31. The display should indicate: 0031 FLO |
OK: GO TO step 4 NOT OK: Check INFO-TRAK Monitor |
| 4 - Calibrate float system. |
With the raise/lower rocker switch on the multifunction control handle, lower the header until it is about 100 mm above ground level (the header must not touch the ground). Press the fan speed knob on the INFO-TRAK monitor. The display indicates: 0031 HFL Press the resume to float knob on the multifunction control handle. The display should indicate: 0031 EOC |
OK: GO TO step 5 NOT OK: Header does not raise or lower, check system hydraulics NOT OK: Display does not change to "HFL", make sure header raise/lower rocker switch is off. See your nearest dealer NOT OK: "E5X" or "E39" on display indicates an error. See your nearest dealer NOT OK: The display does not change, continuously shows "HFL". See your nearest dealer |