Filling up CCS Tanks

A34471
A34471-UN-11OCT88

A49921
A49921-UN-20AUG02


CAUTION: Do not operate CCS fan unless the seed tank covers are installed. Harmful chemicals may escape and the seed lines will become obstructed.

Follow chemical manufacturers' instructions when handling parts that have come into contact with chemically treated seeds. Use gloves, safety goggles and a breathing mask.

IMPORTANT: Clean any deposited seed treatment chemical or talc before refilling CCS tank.

Before filling up seed tanks, clean the level sensor.

Talc Application Rate

Unit Size

Talc Quantity

1127 L (32 bu) tank

2.4 L (10 Cup)

Adjust these rates as necessary, ensuring that the seeds are covered in talc so as to avoid the build-up of talc at the bottom of the tank.

Double the talc sprinkle rate for small seeds, very large corn seeds, seeds requiring increased levels of treatment and when planting in wet conditions.

IMPORTANT: To guarantee suitable planting, the seeds and chemical treatment mix must not form clots.

NOTE: The talc may be mixed proportionally and fully while the seeds are being placed in the tanks.

ML70882,000045F-19-20060317