Automatic Unloading Device
There is a safety device that is activated by a cable and does not allow the unloading auger to be driven if the tube is not in the working position. The steel cable must be tensioned when the unloading auger is open.
Before adjusting the cable, remove the side panel from the lever console, left hand side, and open the left hand side shield.
Adjust the cable (A) with the adjusting nut (B) so that length (X) is of 39 mm.
Once the adjustment is done, fasten the nut (B) with the jam nut (G).
If the cable is overstretched, shorten it with the clamp (E).
A - Cable
B - Adjusting Nut
C - Sheave
D - Guide Sheave
E - Clamp
G - Jam Nut
X - 39 mm
|