Every 2000 Hours or 2 Years
-
IMPORTANT: When COOL-GARD II or COOL-GARD II PG is used, the drain interval is 6 years or 6000 hours of operation. If a coolant other than COOL-GARD II or COOL-GARD II PG is used, reduce the drain interval to 2 years or 2000 hours
of operation.

CQ280437-UN-27AUG08

H91173-UN-17APR08
A - Drain
B - Surge Tank
Radiator - Open drain (A) to remove coolant from radiator.
-
NOTE: Air becomes trapped in Exhaust Gas Recirculation (EGR)
cooler during the coolant fill operation. This trapped air will cause
severe damage to cooler and turbo charger. Use proper filling and
bleeding procedure shown in Service Engine section to avoid damage
to components.
Surge Tank - Flush and refill with correct coolant and conditioner
(see Cooling System—Draining in Service Engine section and Engine
Coolant recommendations given in Fuels and Lubricants section). Check
engine coolant level in surge tank (B) with engine cold. Level must
be up to “Max Cold” line.
|