Every 200 Hours

  1. IMPORTANT:

    CQ280387
    CQ280387-UN-27AUG08

    H86772
    H86772-UN-02NOV06

    Separator Variable Speed Driven and Driver Sheaves: Pump 20 to 25 shots of grease into fitting. DO NOT OVER GREASE.

    Separator Variable Speed Driven Sheaves - Rotate sheaves to access fitting.



  2. NOTE: Start machine and cycle separator through full speed range a couple of times to distribute grease evenly.

    Separator Variable Speed Driver Sheave - Close sheaves (high speed) before greasing fitting on outer sheave hub. Rotate sheave to access fitting. Cycle cylinder speed to distribute grease if operated at high speed all the time.

GB52027,0000611-19-20080704