Chaffer/Sieve Remote Shoe Adjust Motor (Self-Leveling Shoe)—Manual
Adjust
-
CAUTION: Shut OFF engine, set parking brake and remove key to
help prevent accidental starting and personal injury.
NOTE: Same manual adjust procedure can be used on chaffer or
sieve motor. Two center chaffer bays must be removed to
adjust sieve bay motor.

H91029-UN-26MAR08
A - Cap Screws (4 Used)
B - Cap Screws (4 Used)
C - Cap Screws (3 Used)
D - Shield
Remove cap screws (A—C) and shield (D).
-
IMPORTANT: To prevent adjusting motor damage, do not use wrench
on knob.

H91057-UN-31MAR08
A - Knob
Use knob (A) to adjust motor. Turn knob clockwise to close
and counterclockwise to open chaffer/sieve.
-
NOTE: Motor must be calibrated if it is repaired or replaced,
see Calibration Procedures section.

H91245-UN-22APR08
A - Distance
B - Adjust Motor
C - Linkage Bar
Distance (A) between adjust motors (B) and linkage bar (C)
must be set the same to allow louvers to open and close freely.
|
|
OUO6075,0000070-19-20080424
|
|