Calibration Procedures - When to Calibrate
This list shows all possible calibrations. Depending on machine
options and header types, listing shown might not match calibration
menu shown on display.
NOTE: Error codes show on display if a problem exists during
a calibration procedure. Conditions causing error must be corrected
before continuing calibration.
-
IMPORTANT: Threshing Clearance Calibration should not be completed
with round bar concave covers installed. An incorrect zero position
may result.
Threshing Clearance Calibration - Perform
calibration when control unit LC1, threshing clearance sensor, or
associated components are replace/adjusted.
-
Header Calibration - Perform calibration;
-
If control unit LC1 has been replaced.
-
If a header height control sensor or associated components are
replaced/adjusted.
-
First time each header is connected to combine.
-
Feeder House Speed Calibration - Perform
calibration;
-
If control unit LC1 has been replaced.
-
First time each header is connected to combine.
-
If attachments of significant weight is added to or removed
from head.
-
Chaffer Opening Calibration - Perform
calibration when control unit LC2 or chaffer actuator has been replaced/adjusted
or louver openings are out of adjustment.
-
Sieve Opening Calibration - Perform
calibration when control unit LC2 or sieve actuator has been replaced/adjusted
or louver openings are out of adjustment.
-
NOTE: When prompted during self-leveling shoe calibration to
level chaffer and sieve, use switches on side of machine to level
bays.
Self-Leveling Shoe Calibration (If Equipped)
- Perform calibration when control unit LC2 or chaffer/sieve
actuator has been replaced/adjusted or bays are not level.
-
Corn Head Deck Plate Calibration - Perform calibration when control unit LC1 or deck plate position
sensor or associated components are replaced/adjusted.
-
Smart Feed Rate Handle Calibration (If Equipped)
- Perform calibration when control unit VCM, handle position
sensor are replaced/adjusted.
-
Smart Feed Rate Valve Calibration (If Equipped)
- Perform calibration when control unit VCM, forward solenoid,
or reverse solenoid has been replaced.
-
NOTE: Moisture sensor must be calibrated if any of the following
conditions exist:
• Moisture sensor readings inaccurate.
• Moisture sensor shows “moisture unmeasurable”
warnings.
• Moisture sensor HMM or related components were replaced.
Moisture Calibration (If Equipped) - Perform calibration when control unit HMM or associated components
are replaced/adjusted.
-
NOTE: Mass flow sensor must be calibrated every year to achieve
accurate grain weight measurements.
Standard calibration
must be performed in every crop that is harvested.
Low Flow calibration must be performed to obtain improved levels
of accuracy in situations where large variations in grain flow rates
occur. Refer to Yield Calibration in CommandCenter Display Screens
section for more information.
Yield Calibration (If Equipped) - Perform
calibration when control unit HMM or associated components are replaced/adjusted.
-
Service Hours Calibration - Reset
Service Hours.
-
Feeder House Tilt Calibration (If Equipped)
- Perform calibration;
-
If control unit LC1 has been replaced.
-
If lateral tilt sensor or associated components are replaced/adjusted.
-
First time each header is connected to combine.
|
|