Standard Speed High Capacity Feed Accelerator—Changing
NOTE: When changing separator speeds make sure to cycle power
ON and OFF. Combine will now recognize the new speed range.

H74782-UN-14JAN03

H86423-UN-28JUL06
A - Lever
B - Notch in Bracket
C - Belt
To change feed accelerator speed to high speed position:
-
Remove belt tension by pushing lever (A) up and out from notch
in bracket (B).
-
Move belt (C) to inside sheave grooves on both sheaves for high
speed.
-
Push lever up and into notch in bracket to reset belt tension.
|
|
OUO6075,0000747-19-20070716
|
|