RCU
|
126
|
12
|
Service Alert
|
Five speed feeder house filter (cc# 738) problem detected when
separator is not engaged.
|
|
RCU
|
127
|
03
|
Service Alert
|
Five speed feeder house pressure (cc# 737) sensor voltage is
out of range - greater than 4.93 VDC.
|
|
RCU
|
127
|
04
|
Service Alert
|
Five speed feeder house pressure (cc# 737) sensor voltage is
out of range - less than 0.20 VDC.
|
|
RCU
|
127
|
12
|
Service Alert
|
Five speed feeder house pressure (cc# 737) is detected when
separator is not running.
|
|
RCU
|
629
|
12
|
Service Alert
|
Control unit RCU has reset itself due to watchdog timer.
|
|
RCU
|
1075
|
03
|
Stop
|
Fuel transfer pump (cc# 188) is ON when not commanded by right
power module.
|
|
RCU
|
1075
|
05
|
Service Alert
|
Fuel transfer pump (cc# 188) is open circuit.
|
|
RCU
|
1075
|
06
|
Service Alert
|
Fuel transfer pump (cc# 188) is OFF when commanded ON by right
power module.
|
|
RCU
|
1231
|
09
|
Service Alert
|
Message is not arriving on time or missing on local CAN Bus
between the control unit RCU and right power module.
|
|
RCU
|
1488
|
03
|
Service Alert
|
Threshing speed (cc# 609) signal voltage feedback is out of
range - greater than 4.90 VDC.
|
|
RCU
|
1488
|
04
|
Service Alert
|
Threshing speed (cc# 609) signal voltage feedback is out of
range - less than 0.10 VDC.
|
|
RCU
|
1489
|
03
|
Service Alert
|
Cleaning fan speed (cc# 606) signal voltage feedback is out
of range - greater than 4.90 VDC.
|
|
RCU
|
1489
|
04
|
Service Alert
|
Cleaning fan speed (cc# 606) signal voltage feedback is out
of range - less than 0.10 VDC.
|
|
RCU
|
1490
|
03
|
Service Alert
|
Feeder house speed (cc# 619) signal voltage feedback is out
of range - greater than 4.90 VDC.
|
|
RCU
|
1490
|
04
|
Service Alert
|
Feeder house speed (cc# 619) signal voltage feedback is out
of range - less than 0.10 VDC.
|
|
RCU
|
1493
|
12
|
Service Alert
|
Tailings monitor system failure. Tailings sensors have read
the same value for 10 seconds and are not full.
|
|
RCU
|
1533
|
00
|
Calibration
|
Feeder house tilt sensor (cc# 815) is out of range at right
position - greater than 4.5 VDC.
|
|
RCU
|
1533
|
01
|
Calibration
|
Feeder house tilt sensor (cc# 815) is out of range at left position
- less than 0.5 VDC.
|
|
RCU
|
1533
|
03
|
Service Alert
|
Feeder house tilt sensor (cc# 815) is out of range - greater
than 4.5 VDC.
|
|
RCU
|
1533
|
04
|
Service Alert
|
Feeder house tilt sensor (cc# 815) is out of range - less than
0.5 VDC.
|
|
RCU
|
1533
|
08
|
Calibration
|
Feeder house tilt sensor (cc# 815) voltage is greater at left
position than right position.
|
|
RCU
|
1533
|
13
|
Information
|
Feeder house tilt sensor (cc# 815) has not been calibrated.
|
|
RCU
|
1533
|
16
|
Calibration
|
Feeder house tilt sensor (cc# 815) voltage is greater at left
position than Center position.
|
|
RCU
|
1533
|
18
|
Calibration
|
Feeder house tilt sensor (cc# 815) voltage is greater at Center
position than right position.
|
|
RCU
|
1867
|
06
|
Service Alert
|
RPM micro power (cc# 302) is OFF when commanded ON by Control
unit RCU.
|
|
RCU
|
3020
|
03
|
Stop
|
Auger engage (cc# 319) is ON when not commanded by control unit
RCU.
|
|
RCU
|
3020
|
05
|
Service Alert
|
Auger engage (cc# 319) is open circuit.
|
|
RCU
|
3020
|
06
|
Service Alert
|
Auger engage (cc# 319) is OFF when commanded ON by control unit
RCU.
|
|
RCU
|
3020
|
14
|
Service Alert
|
Auger engage (cc# 319) is OFF when commanded ON by control unit
RCU, but there is no detected problem.
|
|
RCU
|
3108
|
03
|
Service Alert
|
Spreader speed 1 high side (cc# 343) is ON when not commanded
by control unit RCU.
|
|
RCU
|
3108
|
04
|
Service Alert
|
Spreader speed 1 high side (cc# 343) is OFF when commanded ON
by control unit RCU.
|
|
RCU
|
3108
|
05
|
Service Alert
|
Spreader speed 1 high side (cc# 343) is open circuit.
|
|
RCU
|
3108
|
06
|
Service Alert
|
Spreader speed 1 high side (cc# 343) is OFF when commanded ON
by control unit RCU.
|
|
RCU
|
3108
|
14
|
Service Alert
|
Spreader speed 1 high side (cc# 343) is OFF when commanded ON
by control unit RCU, but there is no detected problem.
|
|
RCU
|
3353
|
03
|
Service Alert
|
Alternator field (cc# 007) is ON when not commanded by control
unit RCU.
|
|
RCU
|
3353
|
05
|
Service Alert
|
Alternator field (cc# 007) is open circuit.
|
|
RCU
|
3353
|
06
|
Service Alert
|
Alternator field (cc# 007) is OFF when commanded ON by control
unit RCU.
|
|
RCU
|
3353
|
14
|
Service Alert
|
Alternator field (cc# 007) is OFF when commanded ON by control
unit RCU, but there is no detected problem.
|
|
RCU
|
3509
|
03
|
Service Alert
|
RCU 5V sensor supply (cc# 293) is out of range - greater than
5.5 VDC.
|
|
RCU
|
3509
|
04
|
Service Alert
|
RCU 5V sensor supply (cc# 293) is out of range - less than 4.5
VDC.
|
|
RCU
|
3510
|
03
|
Service Alert
|
RCU 8V sensor supply (cc# 297) is out of range - greater than
8.5 VDC.
|
|
RCU
|
3510
|
04
|
Information
|
RCU 8V sensor supply (cc# 297) is out of range - less than 7.5
VDC.
|
|
RCU
|
3597
|
06
|
Information
|
RCU PTC power (cc# 562) is out of range - less than 4.0 VDC.
|
|
RCU
|
523319
|
03
|
Service Alert
|
RCU 12V switched power (cc# 822) is ON when not commanded by
control unit RCU.
|
|
RCU
|
523319
|
06
|
Service Alert
|
RCU 12V switched power (cc# 822) is OFF when commanded ON by
control unit RCU.
|
|
RCU
|
523489
|
03
|
Service Alert
|
Engine service lights (cc# 531) are ON when not commanded by
right power module.
|
|
RCU
|
523489
|
05
|
Service Alert
|
Engine service lights (cc# 531) are open circuit.
|
|
RCU
|
523489
|
06
|
Service Alert
|
Engine service lights (cc# 531) are OFF when commanded ON by
right power module.
|
|
RCU
|
523493
|
12
|
Service Alert
|
Main gearcase filter (cc# 701) problem detected when engine
is not running.
|
|
RCU
|
523494
|
03
|
Service Alert
|
Right row finder light (cc# 523) is ON when not commanded by
control unit RCU.
|
|
RCU
|
523494
|
05
|
Service Alert
|
Right row finder light (cc# 523) is open circuit.
|
|
RCU
|
523494
|
06
|
Service Alert
|
Right row finder light (cc# 523) is OFF when commanded ON by
control unit RCU.
|
|
RCU
|
523501
|
12
|
Service Alert
|
Main gearcase pressure (cc# 703) is detected when engine is
not running.
|
|
RCU
|
523574
|
03
|
Service Alert
|
Main gearcase temp sensor (cc# 754) is out of range - greater
than 4.93 VDC.
|
|
RCU
|
523574
|
04
|
Service Alert
|
Main gearcase temp sensor (cc# 754) is out of range - less than
0.10 VDC.
|
|
RCU
|
523594
|
03
|
Service Alert
|
Shoe service lights (cc# 595) is ON when not commanded by right
power module.
|
|
RCU
|
523594
|
05
|
Service Alert
|
Shoe service lights (cc# 595) is open circuit.
|
|
RCU
|
523594
|
06
|
Service Alert
|
Shoe service lights (cc# 595) is OFF when commanded ON by right
power module.
|
|
RCU
|
523595
|
03
|
Service Alert
|
Lower driving lights (cc# 586) is ON when not commanded by right
power module.
|
|
RCU
|
523595
|
05
|
Service Alert
|
Lower driving lights (cc# 586) is open circuit.
|
|
RCU
|
523595
|
06
|
Service Alert
|
Lower driving lights (cc# 586) is OFF when commanded ON by right
power module.
|
|
RCU
|
523597
|
03
|
Service Alert
|
Rear beacon lights (cc# 574) is ON when not commanded by right
power module.
|
|
RCU
|
523597
|
05
|
Service Alert
|
Rear beacon lights (cc# 574) is open circuit.
|
|
RCU
|
523597
|
06
|
Service Alert
|
Rear beacon lights (cc# 574) is OFF when commanded ON by right
power module.
|
|
RCU
|
523598
|
06
|
Service Alert
|
Cleaning fan speed decrease (cc# 326) is OFF when commanded
ON by control unit RCU.
|
|
RCU
|
523599
|
03
|
Service Alert
|
Cleaning fan speed increase (cc# 325) and/or cleaning fan speed
decrease (cc# 326) is ON when commanded OFF by control unit RCU.
|
|
RCU
|
523599
|
05
|
Service Alert
|
Cleaning fan speed increase (cc# 325) and/or cleaning fan speed
decrease (cc# 326) is open circuit.
|
|
RCU
|
523599
|
06
|
Service Alert
|
Cleaning fan speed increase (cc# 325) is OFF when commanded
ON by control unit RCU.
|
|
RCU
|
523600
|
06
|
Service Alert
|
Grain tank covers open (cc# 336) is OFF when commanded ON by
control unit RCU.
|
|
RCU
|
523601
|
03
|
Service Alert
|
Grain tank covers close (cc# 335) and/or Grain tank covers open
(cc# 336) is ON when commanded OFF by control unit RCU.
|
|
RCU
|
523601
|
05
|
Service Alert
|
Grain tank covers close (cc# 335) and/or Grain tank covers open
(cc# 336) is open circuit.
|
|
RCU
|
523601
|
06
|
Service Alert
|
Grain tank covers close (cc# 335) is OFF when commanded ON by
control unit RCU.
|
|
RCU
|
523602
|
03
|
Service Alert
|
Five speed feeder house drive valve 5 (cc# 448) is ON when not
commanded by control unit RCU.
|
|
RCU
|
523602
|
04
|
Service Alert
|
Five speed feeder house drive valve 5 (cc# 448) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523602
|
05
|
Service Alert
|
Five speed feeder house drive valve 5 (cc# 448) is open circuit.
|
|
RCU
|
523602
|
06
|
Service Alert
|
5 speed feeder house drive valve 5 (cc# 448) is OFF when commanded
ON by control unit RCU.
|
|
RCU
|
523603
|
03
|
Service Alert
|
Five speed feeder house drive valve 4 (cc# 447) is ON when not
commanded by control unit RCU.
|
|
RCU
|
523603
|
05
|
Service Alert
|
Five speed feeder house drive valve 4 (cc# 447) is open circuit.
|
|
RCU
|
523603
|
06
|
Service Alert
|
Five speed feeder house drive valve 4 (cc# 447) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523603
|
06
|
Service Alert
|
Five speed feeder house drive valve 4 (cc# 447) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523604
|
03
|
Service Alert
|
Five speed feeder house drive valve 3 (cc# 446) is ON when not
commanded by control unit RCU.
|
|
RCU
|
523604
|
04
|
Service Alert
|
Five speed feeder house drive valve 3 (cc# 446) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523604
|
05
|
Service Alert
|
Five speed feeder house drive valve 3 (cc# 446) is open circuit.
|
|
RCU
|
523604
|
06
|
Service Alert
|
Five speed feeder house drive valve 3 (cc# 446) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523605
|
03
|
Service Alert
|
Five speed feeder house drive valve 2 (cc# 445) is ON when not
commanded by control unit RCU.
|
|
RCU
|
523605
|
04
|
Service Alert
|
Five speed feeder house drive valve 2 (cc# 445) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523605
|
05
|
Service Alert
|
Five speed feeder house drive valve 2 (cc# 445) is open circuit.
|
|
RCU
|
523605
|
06
|
Service Alert
|
Five speed feeder house drive valve 2 (cc# 445) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523606
|
03
|
Service Alert
|
Five speed feeder house drive valve 1 (cc# 444) is ON when
not commanded by control unit RCU.
|
|
RCU
|
523606
|
04
|
Service Alert
|
Five speed feeder house drive valve 1 (cc# 444) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523606
|
05
|
Service Alert
|
Five speed feeder house drive valve 1 (cc# 444) is open circuit.
|
|
RCU
|
523606
|
06
|
Service Alert
|
Five speed feeder house drive valve 1 (cc# 444) is OFF when
commanded ON by control unit RCU.
|
|
RCU
|
523611
|
03
|
Service Alert
|
Right rear discharge light (cc# 565) is ON when not commanded
by control unit RCU.
|
|
RCU
|
523611
|
05
|
Service Alert
|
Right rear discharge light (cc# 565) is open circuit.
|
|
RCU
|
523611
|
06
|
Service Alert
|
Right rear discharge light (cc# 565) is OFF when commanded ON
by control unit RCU.
|
|
RCU
|
523611
|
14
|
Service Alert
|
Right rear discharge light (cc# 565) is OFF when commanded ON
by control unit RCU, but there is no detected problem.
|
|
RCU
|
523612
|
03
|
Service Alert
|
Right stubble light (cc# 563) is ON when not commanded by control
unit RCU.
|
|
RCU
|
523612
|
05
|
Service Alert
|
Right stubble light (cc# 563) is open circuit.
|
|
RCU
|
523612
|
06
|
Service Alert
|
Right stubble light (cc# 563) is OFF when commanded ON by control
unit RCU.
|
|
RCU
|
523612
|
14
|
Service Alert
|
Right stubble light (cc# 563) is OFF when commanded ON by control
unit RCU, but there is no detected problem.
|
|
RCU
|
523613
|
03
|
Service Alert
|
Spreader speed 2 high side (cc# 353) is ON when not commanded
by control unit RCU.
|
|
RCU
|
523613
|
04
|
Service Alert
|
Spreader speed 2 high side (cc# 353) is OFF when commanded ON
by control unit RCU.
|
|
RCU
|
523613
|
05
|
Service Alert
|
Spreader speed 2 high side (cc# 353) is open circuit.
|
|
RCU
|
523613
|
06
|
Service Alert
|
Spreader speed 2 high side (cc# 353) is OFF when commanded ON
by control unit RCU.
|
|
RCU
|
523613
|
14
|
Service Alert
|
Spreader speed 2 high side (cc# 353) is OFF when commanded ON
by control unit RCU, but there is no detected problem.
|
|
RCU
|
523614
|
03
|
Service Alert
|
Right marker lights (cc# 553) is ON when not commanded by control
unit RCU.
|
|
RCU
|
523614
|
05
|
Service Alert
|
Right marker lights (cc# 553) is open circuit.
|
|
RCU
|
523614
|
06
|
Service Alert
|
Right marker lights (cc# 553) is OFF when commanded ON by control
unit RCU.
|
|
RCU
|
523614
|
14
|
Service Alert
|
Right marker lights (cc# 553) output driver fault.
|
|
RCU
|
523615
|
03
|
Stop
|
Separator engage (cc# 301) is ON when not commanded by control
unit RCU.
|
|
RCU
|
523615
|
05
|
Service Alert
|
Separator engage (cc# 301) is open circuit.
|
|
RCU
|
523615
|
06
|
Service Alert
|
Separator engage (cc# 301) is OFF when commanded ON by control
unit RCU.
|
|
RCU
|
523615
|
14
|
Service Alert
|
Separator engage (cc# 301) is OFF when commanded ON by control
unit RCU, but there is no detected problem.
|
|
RCU
|
523616
|
03
|
Service Alert
|
Discharge beater speed (cc# 611) signal voltage feedback is
out of range - greater than 4.90 VDC.
|
|
RCU
|
523616
|
04
|
Service Alert
|
Discharge beater speed (cc# 611) signal voltage feedback is
out of range - less than 0.10 VDC.
|
|
RCU
|
523617
|
03
|
Service Alert
|
Capacitive fuel level 2 sensor (cc# 756) is out of range - greater
than 4.5 VDC.
|
|
RCU
|
523617
|
04
|
Service Alert
|
Capacitive fuel level 2 sensor (cc# 756) is out of range - less
than 0.2 VDC.
|
|
RCU
|
523618
|
03
|
Service Alert
|
Capacitive fuel level 1 sensor (cc# 755) is out of range - greater
than 4.5 VDC.
|
|
RCU
|
523618
|
04
|
Service Alert
|
Capacitive fuel level 1 sensor (cc# 755) is out of range - less
than 0.2 VDC.
|
|
RCU
|
523619
|
03
|
Service Alert
|
Resistive fuel level 2 sensor (cc# 756) is out of range - greater
than 4.5 VDC.
|
|
RCU
|
523619
|
04
|
Service Alert
|
Resistive fuel level 2 sensor (cc# 756) is out of range - less
than 0.2 VDC.
|
|
RCU
|
523620
|
03
|
Service Alert
|
Resistive fuel level 1 sensor (cc# 755) is out of range - greater
than 4.5 VDC.
|
|
RCU
|
523620
|
04
|
Service Alert
|
Resistive fuel level 1 sensor (cc# 755) is out of range - less
than 0.2 VDC.
|
|
RCU
|
523621
|
13
|
Information
|
Threshing clearance (cc# 833) has not been calibrated
|
|
RCU
|
523622
|
04
|
Information
|
RPC power 5 (cc# 362) less than 10.5 VDC at the right power
module input.
|
|
RCU
|
523623
|
03
|
Service Alert
|
RCU 12V switched power 2 (cc# 922) is ON when not commanded
by control unit RCU.
|
|
RCU
|
523623
|
06
|
Service Alert
|
RCU 12V switched power 2 (cc# 922) is OFF when commanded ON
by control unit RCU.
|
|
RCU
|
523648
|
04
|
Information
|
RPC power 4 (cc# 352) less than 10.5 VDC at the right power
module input.
|
|
RCU
|
523649
|
04
|
Information
|
RPC power 3 (cc# 332) less than 10.5 VDC at the right power
module input.
|
|
RCU
|
523650
|
04
|
Information
|
RPC power 2 (cc# 322) less than 10.5 VDC at the right power
module input.
|
|
RCU
|
523653
|
04
|
Information
|
RPC power 1 (cc# 312) less than 10.5 VDC at the right power
module input.
|
|
RCU
|
523665
|
04
|
Information
|
RCU power 1 (cc# 342) at connector X132 is less than 4.0 VDC.
|
|
RCU
|
523666
|
04
|
Information
|
RCU power 1 (cc# 342) at connector X131 is less than 4.0 VDC.
|
|
RCU
|
523673
|
05
|
Information
|
Chassis ground (cc# 010) not connected to ground.
|
|
RCU
|
523744
|
03
|
Service Alert
|
HVAC compressor (cc# 941) is ON when not commanded by control
unit RCU.
|
|
RCU
|
523744
|
05
|
Service Alert
|
HVAC compressor (cc# 941) is open circuit.
|
|
RCU
|
523744
|
06
|
Service Alert
|
HVAC compressor (cc# 941) is OFF when commanded ON by control
unit RCU.
|
|
RCU
|
523744
|
14
|
Service Alert
|
HVAC compressor (cc# 941) is OFF when commanded ON by control
unit RCU, but there is no detected problem.
|
|
RCU
|
523810
|
03
|
Service Alert
|
Steering solenoid power (cc# 942) is ON when not commanded by
control unit RCU.
|
|
RCU
|
523810
|
06
|
Service Alert
|
Steering solenoid power (cc# 942) is OFF when commanded ON by
control unit RCU.
|
|
RCU
|
524084
|
03
|
Service Alert
|
Hydraulic oil temp sensor (cc# 753) is out of range - greater
than 4.93 VDC.
|
|
RCU
|
524084
|
04
|
Service Alert
|
Hydraulic oil temp sensor (cc# 753) is out of range - less than
0.10 VDC.
|