HMM
|
629
|
12
|
Information
|
Moisture sensor has reset itself due to watchdog timer.
|
|
HMM
|
3509
|
18
|
Service Alert
|
AMS power (cc# 912) voltage too low, less than 8V. Data may
be lost when key switch is turned off.
|
|
HMM
|
3510
|
16
|
Service Alert
|
Mass flow sensor supply (cc# 938) voltage too high, greater
than 5.35V.
|
|
HMM
|
3510
|
18
|
Service Alert
|
Mass flow sensor supply (cc# 938) voltage too low, less than
4.65V.
|
|
HMM
|
3511
|
16
|
Service Alert
|
Internal analog voltage too high, greater than 2.7V.
|
|
HMM
|
3511
|
18
|
Service Alert
|
Internal analog voltage too low, less than 2.3V.
|
|
HMM
|
201000
|
02
|
Information
|
Grain is too dry to measure.
|
|
HMM
|
522878
|
16
|
Service Alert
|
Over temperature. Moisture sensor will not operate when temperature
is greater than 85 ºC.
|
|
HMM
|
523105
|
12
|
Service Alert
|
Motor failed to move plunger.
|
|
HMM
|
523105
|
14
|
Service Alert
|
Motor failed to move plunger during initialization.
|
|
HMM
|
523106
|
11
|
Service Alert
|
Relay failure.
|
|
HMM
|
523107
|
06
|
Service Alert
|
Motor shorted.
|
|
HMM
|
523107
|
07
|
Service Alert
|
Plunger initialization failure.
|
|
HMM
|
523313
|
03
|
Service Alert
|
Mass flow sensor signal (cc# 939) is too high.
|
|
HMM
|
523313
|
04
|
Service Alert
|
Mass flow sensor signal (cc# 939) is too low.
|
|
HMM
|
523316
|
18
|
Service Alert
|
RCU 12V switched voltage (cc# 922) too low, less than 10V.
|