CCU Test Procedures

Display Addresses Air filter Circuit Description Display / Specification
Nominal Value
Range
1   Error codes stored    
2   Go to address 0019    
3 B49 Separator transmission pressure 35 bar (507.6 psi) 35 - 42 bar (507.6 - 609.16 psi)
4 B51 Header transmission pressure 14 bar (203 psi) 12 - 17 bar (174 - 246.5 psi)
5 B50 Auger transmission pressure 12 bar (174 psi) 10 - 15 bar (145 - 217.5 psi)
6 B07 Hydraulic oil return pressure 1.5 bar (21.75 psi) 0 - 5 bar (0 - 72.5 psi)
7 B4 Engine water temperature 105 °C (221 °F)  
8 B8 Hydraulic oil temperature 95 °C (203 °F)  
9 B3 Air conditioning temperature    
10 B13 A/C temperature adjustment potentiometer    
11 B5 Reel speed    
12 B9 Reel speed adjustment potentiometer   0.93 - 3.96 Volts
13 B16 Straw chopper speed   2000 - 3600 rpm
14 B19 Clean grain elevator speed 450 rpm  
15 B17 Tailings elevator speed 320 rpm  
16 B20 Straw walker speed 160 rpm  
17 B24 Power Separator speed 160 rpm  
18 B11 Fuel sensor   1.32 - 1.92 Volts
19   Atmospheric pressure transducer 1.6 Volts  
20   Fuel density 850 g/L 800 - 950 g/L
21   Fuel capacity   0 - 485 L
22   Power supply #1 12 Volt  
23   Power supply #2 12 Volt  
24   Power supply #3 12 Volt  
25   Sensor power 5 Volt  
26   Engine maximum rpm 2400 rpm 2200 - 2600 rpm
27   Unloading auger position 5% 5 - 50%
28   Unloading auger swing out time 14 sec. 8 - 18 sec.
29   Reel speed preferred mode   0001 = Manual
0002 = Automatic

 

AS60558,0001095 -19-21JAN09-1/2


Display Addresses Air filter Circuit Description Display / Specification
Nominal Value
Range
30   Console keys status 0000 = No key.
0001 = Separator key.
0010 = Header key.
0100 = Unloading auger key.
1000 = Unloading auger swing out key.
2000 = Unloading auger swing in key.
 
31   Armrest keys status 0000 = No key.
0001 = Increase reel speed key.
0002 = Reduce reel speed key.
0010 = Increase separator speed key.
0020 = Reduce separator speed key.
0100 = Increase fan speed key.
0200 = Reduce fan speed key.
1000 = Concave opening increase key.
2000 = Concave opening reduce key.
 
32   Diverse keys status 0000 = No key actuated.
0001 = Reverser key.
0010 = Emergency stop key.
0100 = Operator seat switch.
1000 = Spreader speed increase key.
2000 = Spreader speed reduce key.
 
33   Belt adjustment mode 0001 = Field (default)
0002 = Setting
 

 

AS60558,0001095 -19-21JAN09-2/2