Automatic Header Control System Error Codes-HCU

IMPORTANT: The solution number for the error message is the number (step) of the header test procedure.

Error Codes Error Message Solution
200E System not calibrated  
201E Header height not calibrated  
202E Header float pressure not calibrated  
203E Header height sensors not available 28
209E Slow raise valve engage circuit fault 25
210E Slow lower valve engage circuit fault 25
211E Fast raise valve engage circuit fault 25
212E Fast lower valve engage circuit fault 25
213E Tilt valve engage circuit fault, left-hand side 26
214E Tilt valve engage circuit fault, right-hand side 26
215E Flex pressure diverter valve circuit fault 24
216E Accumulator shutoff valve circuit fault 24
218E Sensor power supply fault 6
220E Height control setting fault 10
221E Float control setting fault 11
224E Feeder house angle sensor fault 13
225E Left-hand cutting height sensor fault 14
226E Right-hand cutting height sensor fault (Sensor out of range) 15
227E Cylinder pressure sensor fault 16
232E Header raise/lower switch fault 8
233E Manual tilt switch fault 8
234E Flex pressure switch fault. 9
235E Reel raise/lower switch fault 8
236E Reel forward switch fault 8
240E Header cutting height sensor fault 21
241E Reel raise/lower position sensor fault (not available) 19
242E Reel forward position sensor fault (not available) 20
243E Reel fast raise valve engage circuit fault 26
244E Reel fast lower valve engage circuit fault 26
245E Reel forward position circuit fault 26
246E Reel aft position circuit fault 26
247E Reel raise/lower setpoint position not reached (not available)  
248E Reel fore/aft setpoint position not reached (not available)  

 

AS60558,00011E6 -19-21JAN09-1/1