CCU Error Codes

Error Codes Error Message Solution
300E Automatic reel speed system inactive  
302E Ground speed sensor signal out of range  
303E No reel speed signal  
304E Reel speed signal out of range  
305E Reel speed pot shorted to ground  
306E Reel speed pot shorted to power  
307E Reel speed pot damaged or disconnected  
311E Reel does not accelerate  
312E Reel does not reduce speed  
316E System voltage above normal range  
317E Threshing cylinder pressure sensor damaged or disconnected  
318E Threshing cylinder pressure sensor shorted to power  
319E Threshing cylinder pressure sensor shorted to ground  
320E Unloading auger pressure sensor damaged or disconnected  
321E Unloading auger pressure sensor shorted to power  
322E Unloading auger pressure sensor shorted to ground  
323E Header drive pressure sensor damaged or disconnected  
324E Header drive pressure sensor shorted to power  
325E Header drive pressure sensor shorted to ground  
326E Coolant temperature sensor damaged or disconnected  
327E Coolant temperature sensor shorted to power  
328E Coolant temperature sensor shorted to ground  
329E Hydraulic oil temperature sensor damaged or disconnected  
330E Hydraulic oil temperature sensor shorted to power  
331E Hydraulic oil temperature sensor shorted to ground  
332E Fuel sensor damaged or disconnected  
333E Fuel sensor shorted to power  
334E Fuel sensor shorted to ground  
339E Separator disengage solenoid damaged or disconnected  
340E Separator disengage solenoid shorted to power  
341E Separator disengage solenoid shorted to ground  
342E Separator engage solenoid damaged or disconnected  
343E Separator engage solenoid shorted to power  
344E Separator engage solenoid shorted to ground  
345E Header disengage solenoid damaged or disconnected  
346E Header disengage solenoid shorted to power  
347E Header disengage solenoid shorted to ground  
348E Header engage solenoid damaged or disconnected  

 

AS60558,00011E7 -19-29JAN09-1/3


Error Codes Error Message Solution
349E Header engage solenoid shorted to power  
350E Header engage solenoid shorted to ground  
351E Unloading auger disengage solenoid damaged or disconnected  
352E Unloading auger disengage solenoid shorted to power  
353E Unloading auger disengage solenoid shorted to ground  
354E Unloading auger engage solenoid damaged or disconnected  
355E Unloading auger engage solenoid shorted to power  
356E Unloading auger engage solenoid shorted to ground  
357E Reverser solenoid damaged or disconnected  
358E Reverser solenoid shorted to power  
359E Load solenoid shorted to ground  
360E Load solenoid damaged or disconnected  
361E Load solenoid shorted to power  
362E Load solenoid shorted to ground  
363E Threshing speed adjustment solenoid damaged or disconnected  
364E Threshing speed adjustment solenoid shorted to power  
365E Threshing speed adjustment solenoid shorted to ground  
366E Reel speed adjustment solenoid damaged or disconnected  
367E Reel speed adjustment solenoid shorted to power  
368E Reel speed adjustment solenoid shorted to ground  
369E Unloading auger swing in solenoid damaged or disconnected  
370E Unloading auger swing in solenoid shorted to power  
371E Unloading auger swing in solenoid shorted to ground  
372E Unloading auger swing out solenoid damaged or disconnected  
373E Unloading auger swing out solenoid shorted to power  
374E Unloading auger swing out solenoid shorted to ground  
375E Air conditioning temperature sensor damaged or disconnected  
376E Air conditioning temperature sensor shorted to power  
377E Air conditioning temperature sensor shorted to ground  
378E Air conditioning adjustment pot damaged or disconnected  
379E Air conditioning adjustment pot shorted to power  
380E Air conditioning adjustment pot shorted to gound  
381E Air conditioning relay output shorted to power  
382E Air conditioning relay output shorted to ground  
383E Fan speed increase output open or disconnected  
384E Fan speed increase output shorted to power  
385E Fan speed increase output shorted to ground  
386E Fan speed reduce output open or disconnected  
387E Fan speed reduce output shorted to power  
388E Fan speed reduce output shorted to ground  

 

AS60558,00011E7 -19-29JAN09-2/3


Error Codes Error Message Solution
389E Concave opening increase output open or disconnected  
390E Concave opening increase output shorted to power  
391E Concave opening increase output shorted to ground  
392E Concave opening reduce output open or disconnected  
393E Concave opening reduce output shorted to power  
394E Concave opening reduce output shorted to ground  

 

AS60558,00011E7 -19-29JAN09-3/3