Header Calibration Procedure-Step by Step

IMPORTANT: Carry out "Preliminary Header Calibration Procedures" before you perform the calibration.

Step Action Go to:
Prepare Header for Calibration Hook up header to combine and ensure header harness is connected to main combine harness. Check that header height sensors are in working condition.
Make sure machine is on a level surface.
GO TO Step 1
1 - Select Diagnostic Mode INFO-TRAK™ monitor is used for diagnostic mode. While pressing the up/down button on INFO-TRAK monitor, turn combine key switch on and start engine.
Display should indicate:
- -
dlA
OK: GO TO Step 2
NOT OK: Check INFO-TRAK Monitor
2 - Select HCU (Header Control Unit) Press the "fan" key on Infotrak until "HCU" is displayed.
Display should indicate:
0000
HCU
OK: GO TO Step 3
NOT OK: See your nearest dealership
3 - Enter header calibration mode Press the up/down key on INFO-TRAK monitor until obtaining address 30.
Display should indicate:
0030
HCU
Press fan speed key on INFO-TRAK monitor to access header calibration mode 30
Display should indicate:
0030
Hdr
OK: GO TO Step 4
NOT OK: Check INFO-TRAK Monitor
4 - Calibrate height system and return-to-cut. Define sensor minimum settings Lower header until it rests fully on ground by "raise/lower" switch on multi-function lever handle.
Left- and right-hand sides of header should contact ground at the same time as the header is lowered. Press "Fan Speed" button on INFO-TRAK monitor.
Display should indicate:
0030
H - d
Press return to cut knob on multi-function control handle.
Display should indicate:
0030
H - U
OK: GO TO Step 5
NOT OK: Header does not rise or lower, check hydraulic system.
NOT OK: Display does not change to "H-U", make sure "raise/lower" switch is off. See your nearest dealership
NOT OK: Display "E5X", "E7X", "E8X" or "E9X" indicates an error. See your nearest dealership
NOT OK: Display does not change from "r-d". See your nearest dealership

 

AS60558,00011E9 -19-21JAN09-1/2


Step Action Go to:
5 - Establish maximum sensor settings. Use raise/lower switch on multi-function control handle to raise header fully. Press return to cut knob on multi-function control handle.
Display should indicate:
0030
EOC
OK: GO TO Step 6
NOT OK: Display "E5X", "E7X", "E8X" or "E9X" indicates an error.
See your nearest dealership
6 - Store header calibration data. Press "Fan Speed" knob on INFO-TRAK monitor to store all calibration values. If no errors occurred during calibration, the following will be displayed:
EOC
E00
END
If any errors occurred during calibration, previous calibration values are kept and display reads:
EOC
Err
END
OK: Calibration is done. GO TO Step 7
NOT OK: See your nearest dealership
7 -
Reset to normal operation.
Turn starter key to position "0" to return automatic control system to normal operation at next machine start-up.  

 

AS60558,00011E9 -19-21JAN09-2/2