| Prepare Header for Calibration. |
Couple header to combine. Make sure machine is on a level surface. |
GO TO Step 1. |
| 1 - Select Diagnostic Mode |
INFO-TRAK™ monitor is used for diagnostic mode. Start up the combine while pressing the up/down key on the INFO-TRAK. Display should indicate: -- dIA |
OK: GO TO Step 2 NOT OK: Check INFO-TRAK Monitor |
| 2 - Select AHC |
Press the "fan" key on Infotrak until "HCU" is displayed. Display should indicate: 0000 HCU |
OK: GO TO Step 3 NOT OK: See your nearest dealership |
| 3 - Enter float calibration mode. |
Press the up/down key on INFO-TRAK monitor until obtaining address 31. Display should indicate: 0031 HCU Press the "Fan Speed" key on the Infotrak to access float calibration mode 31. Display should indicate: 0031 FLO |
OK: GO TO Step 4 NOT OK: Check INFO-TRAK Monitor |
| 4 - Calibrate float system. |
With raise/lower switch on the multi-function control handle, lower header until about 100 mm above ground level (header must not touch ground). Press fan speed knob on INFO-TRAK monitor. Display reads: 0031 HFL Press resume to float knob on multi-function control handle. Display should indicate: 0031 EOC |
OK: GO TO Step 5 NOT OK: Header does not rise or lower, check hydraulic system. NOT OK: Display does not change to "HFL", make sure header raise/lower switch is off. See your nearest dealership NOT OK: Display "E5X" or "E39" indicates an error. See your nearest dealership NOT OK: Display does not change from "HFL". See your nearest dealership |